Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3

Installation

D-POS II is designed to be installed either on a wall (with the
supplied 13 mm mounting socket) or in a junction box with cc 60 mm
using an optional 1 mm mounting socket.
Connect the power input to screw terminals #1 & #2.
Only use AC/DC adaptor provided by NEAT, see Table 7 on page 10 or use
12-24 V
as central power supply. The central power supply must be limited
DC
to supply maximum 36 VA.
To adjust the rotary switches and potentiometers we recommend a flat
screwdriver with a 2.4 x 0.5 mm blade. Use max. 10 meters of cable with
cable area 0.4 mm
D-POS II and its corresponding parts must be installed by a professional fitter.
3.1
Configuration with DIP switches DIP 1 - DIP 8
The DIP switches DIP1 - DIP8 configures some parameters in the
D-POS II. The table below displays the functions for a particular DIP
switch.
Picture 1. PCB DIP Switches
Text
Function
DIP1
Configuration
DIP2
Not used
DIP3
External input mode
DIP4
External input function
DIP5
Relay output source
DIP6
Send radio alarm at tamper
DIP7
Power level, see 3.8
DIP8
Walk test mode on/off
Table 2. DIP Switches (S4) functions
Max cable length LOOP: 10 meters with cable area >0.4 mm
D-POS II - NE41 17028-00 v1.0
or more (AWG 21) for ferrite and loop antennas.
2
On
Computer
N/A
Normally closed
Antenna
Tamper/Antenna error
Yes
High
Active
Off
DIP switches
N/A
Normally open
Radio alarm
Radio received
No
Low
Not active
(AWG 21).