TROUBLESHOOTING
Symptom
A. MEASURE-
MENT IS
NOT
ACCURATE
SERVICE
For warranty consideration, parts,
or other service information, please
contact your local dealer or distributor.
Probable Cause
1. Turbine operated below
minimum rate
2. Turbine partially clogged
with dried liquid
3. Turbine bearings partially
clogged with dried liquid
4. Sealant wrapped around
rotor
5. Installed too close to
fittings
6. Improper connections to
recording device
7. Accuracy needs
verification
Solution
Increase flowrate.
Remove turbine. Clean carefully.
Make sure rotor spins freely.
Remove turbine. Clean carefully.
Make sure rotor spins freely.
Remove turbine. Clear material
from rotor. Make sure rotor spins
freely.
Install correctly. See Installation
Section.
Check all electrical connections.
Reference appropriate installation
instructions.
Complete normal accuracy
verification procedures. Repeat
periodically.
5