Problem
No pressure in the sys-
tem
When the system is
drained, no liquid
escapes via the filling
and flushing units
Other malfunctions
10
Decommissioning, disposal
Dispose of the product in compliance with all applicable directives, standards
and safety regulations.
Electronic components must not be disposed of together with the normal
household waste.
Decommissioning, disposal
Possible reason
Safety valve is defective Replace the safety
Expansion vessel not
tight
Leak in the system
Ball valves and/or are
shut-off closed
-
1. Disconnect the product from mains.
2. Dismount the product (see chapter "Mounting", reverse
sequence of steps).
3. Dispose of the product.
Repair
group assembly
Replace the expansion
vessel
Contact your installer
Set the ball valves to
45 ° position and open
shut-off
Contact the AFRISO
service hotline