5. Before Installing a new fireplace

Several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed.
Nordpeis AS is not
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• distance from firebox to combustible/flammable
materials
• insulation materials/requirements between
fireplace surround and back wall
• size of floor plates in front of fireplace if required
• flue connection between firebox and chimney
• insulation requirements if flue passes through a
flammable wall
Back
150mm
Side
150mm
0,09% / 32 mg/Nm3
0,09% / 37 mg/Nm3 (+1)
157 °C
133 °C (+1)
141945 kJ
144711 kJ (+1)
100% after 4,9 hrs
50% after 14,1 hrs
25% after 21,7 hrs
100% after 5,7 hrs
50% after 13 hrs
25% after 20,5 hrs
84,0%
85,2% (+1)
2,35 kW
2,7 kW (+1)
90-140
300 mm
ca. 610 kg
ca. 717 kg
2 kg
5
1 / hour
1
Chimney Draft
Compared to older models, the clean burning fireplaces
of today put significantly higher demands on the
chimney. Even the best fireplace will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draft increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the fireplace,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper. The product is type
tested and should be connected to a chimney that is
dimensioned for the smoke gas temperature indicated
in the CE declaration. When necessary, contact a
professional in advance
Attention! It is recommended to use a qualified
professional when installing a new fireplace.
Attention! It is recommended to use a qualified
professional when installing a new fireplace.
Distance illustration (FIG 1)
*The illustration indicates the approximate centre height
of the recess for the flue. Consider possible inclination
of the flue prior to making perforating the chimney.
Distortions in floors and walls may also influence the
height, dry stack therefore the fireplace for accurate
height and positioning of the flue/chimney connection. If
a fresh air supply set (accessory) is connected through
the floor, mark where the hole should be.
Attention! Since the inner core is composed of
many layers the connection height may vary by up
to a few centimeters from installation to installation.
Safety distances (FIG 2)
Ensure that the safety distances are complied with.