9.2 Installation

9.2.1 Wall mounting

2
258
1
mm
Appliance with 1000 W
1
Space required for the appliance
2
Centre holes
3
Wall retainer
4
Floor
2
1
mm
Appliances with 1500 -2000 W
1
Space required for the appliance
2
Centre holes
3
Wall retainer
4
Floor
Use the wall retainer with centre holes as a fixing template.
Remove the wall retainer from the appliance by pushing in the two clips with a screwdriver.
»
Place the wall retainer horizontally on the floor. Mark the two centre holes (these two holes are at the exact height of the
»
two lower holes) in the installation wall.
Lift up the wall retainer. The lower holes in the wall retainer should be congruent with the markings on the installation
»
wall. Now mark the upper holes.
Drill holes at all four markings. Secure the wall retainer with suitable fixing materials (screws, rawl plugs).
»
With the vertical slots, you can compensate for an offset fixing hole.
3
28
2
t232
t150
4
3
2
258
t150
4
104