Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description - Stobag SRCR 140 A Anweisungen Und Hinweise Für Den Installateur

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Warnings
• For personal safety it is important to observe all instructions
herein and conserve this document for future consultation.
• This manual contains important safety instructions for
installation. Incorrect installation procedures may lead to
seriously hazardous conditions.
• Partial reading of these instructions will not ensure that the
user exploits the characteristics of this product to the full.

1) Product description

The SRCR 140 A control unit enables the control of a single phase
asynchronous motor, mains powered, with connection types: Down,
Common, Up, used for the automation of awnings, rolling shutters
and similar.
The SRCR 140 A control unit incorporates a radio receiver that oper-
ates at the frequency of 433.92 MHz with rolling code technology to
guarantee optimal safety levels.
Each control unit can memorise up to 30 transmitters in the series
SKIMY (figure 1), which enable the remote control of the unit. In the
30 transmitters, a maximum of 3 SKIROSOL SRCK 610 climatic radio
sensors can be memorised, for the automatic control of the control
unit according to weather conditions.
After each command the motor is powered for approx. 150 seconds;
this time interval can be modified (chapter 4.2 Work time). During this
interval, the electric limit switch in the motor stops movement at the
set position.
The control unit is equipped with an input "P/B" for control of the unit
also by means of and external pushbutton.
Memorisation and programming is possible via the transmitters or direct
via the programming pushbutton (figure 2) on the SRCR 140 A. The
user is guided through the various phases by means of LED signals.
1
SKIMY SRCH
2) Installation
• The product is subject to hazardous electric voltages
• The installation of the SRCR 140 A and automations must
be performed exclusively by technically qualified person-
nel, in observance of current legislation and standards,
and according to these instructions. All connections
must be made with the system disconnected from the
power supply.
• The SRCR 140 A control unit has been especially designed
for insertion in a junction box or wall box; its housing does
2.1) Preliminary checks
• The power supply line must be protected by suitable magnetother-
mal and differential switches.
• A disconnection device must be inserted in the power supply line
from the electrical mains (the distance between the contacts must
be at least 3.5 mm with an overvoltage category of III) or equivalent
20
The SRCR 140 A has been designed for control of a single phase asyn-
chronous motor, mains powered, used for the automations of awnings,
rolling shutters and similar devices; any other use is improper and strictly
prohibited. Installation must be carried out by qualified technical person-
nel in full compliance with current legislation and electrical and safety
standards.
Note. The SRCR 140 A control unit can also manage other types of
transmitter and other operating modes; refer to chapter 4 "Further
Details".
SKIMY SRCW
not feature any protection against water and only basic
protection against contact with solid parts. Never place
the SRCR 140 A in inadequately protected environments.
• Never open or perforate the SRCR 140 A housing; do not
cut the aerial cable under any circumstances: this is sub-
ject to hazardous electric voltages!
system, for example an outlet and relative plug. If the disconnection
device for the power supply is not mounted near the automation, it
must have a locking system to prevent unintentional, unauthorised
connection.
2
SKIMY SRCU
SKIROSOL SRCK 610
www.stobag.com

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis