Herunterladen Diese Seite drucken

Specifications - Monacor security PS-12WP Montageanleitung

12-v-netzgerät für den aussenbereich

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Please unfold page 5. Then you can always see
GB
the operating elements and connections de -
scribed.
1 Operating Elements and Connections
1 OUTPUT terminal: 12 V DC voltage output
2 INPUT terminal: connection to 230 V~/50 Hz
3 Operating indication, indicates the 12 V output volt-
age
4 Cable inlets
a Mounting holes
b Mounting straps
2 Safety Notes
This unit corresponds to all required directives of the
EU and is therefore marked with
WARNING
Leave connection to the 230 V mains
voltage to authorized personnel. Con-
tact with the mains volt age is danger-
ous to life!
G
Do not operate the unit and immediately disconnect
it from the mains socket
1. if there is visible damage to the unit or to mains
cable,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by author ized
personnel.
G
Do not use any strong detergents or chemicals for
cleaning.
G
No guarantee claims for the unit and no liability for
any resulting personal damage or material damage
will be accepted if the unit is used for other purposes
than originally intended, if it is not installed in the
correct way or if it is not repaired in an expert way.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a
disposal which is not harmful to the environ-
ment.
3 Applications
The regulated power supply unit PS-12WP has espe-
cially been designed for the power supply of video
monitoring cameras. It can also be used for other 12 V
units if their current consumption does not exceed
500 mA. Due to the weatherproof housing (IP 66), the
power supply unit is suitable for outdoor use.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
7
4 Mounting
G
The unit can be fixed by means of the four mounting
holes (a). For spacing of the mounting holes use fig. 2.
straps (b) is more favourable, fix the straps to the
housing with the supplied screws [use mounting holes
(a)]. Fig. 3 shows the spacing of the mounting holes
for the mounting straps.
5 Electrical Connection
1) Collect the 12 V output voltage at the OUTPUT ter-
.
2) Use a round cable with a diameter of 3 – 6 mm for
3) After applying the mains voltage, the LED (3)
4) After connection, close the housing and fasten the

6 Specifications

Mains input voltage: . . . . . . . 230 V~/50 Hz
Power consumption: . . . . . . 9 VA
Output voltage: . . . . . . . . . . 12 V
Continuous output current: . max. 500 mA
Protective class: . . . . . . . . . . IP 66
Dimensions: . . . . . . . . . . . . . 80 × 70 × 205 mm
Weight: . . . . . . . . . . . . . . . . . 790 g
Subject to technical modification.
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®
The mounting location should be protected against
direct sunlight, if possible. Otherwise the power
supply unit will heat up considerably which will
reduce the life of the components.
If mounting by means of the supplied mounting
minal (1). The correct polarity must be observed in
any case, otherwise the connected unit may be
damaged. Use a round cable with a diameter of
3 – 6 mm to obtain a watertight sealing of the cable
inlet.
the mains connection. Connect the phase to con-
tact "L" of the INPUT terminal (2) and the neutral
conductor to contact "N".
should light up. If it fails to light up, switch off or dis-
connect the mains voltage. Check the fine-wire
fuses and replace them, if required (encapsulated
fuse for the 230 V circuit, non-encapsulated fuse
for the 12 V output).
Do not switch on or connect the mains voltage
again until the connection of the consumer has
been checked for short circuit and the correct
polarity.
screw caps of the cable inlets.

Werbung

loading