Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - GMP E 140.30 Bedienungs- Und Wartungsanleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
6.
Remove protection plate (pos. 15) with a setscrew wrench M3.
7.
Position the new roller after having mounted supports as on the
original one. Centre the roller between the side plates.
8.
Reassemble the ironer following above listed operations.
TROUBLE
Upon switching on the ironer does
not work.
The roller does not turn and the
ironing plate does not drop.
After adjusting the temperature by
means of the thermostat, the iron-
ing plate does not heat.
N.B.: All checks and any technical work must be carried out by fully competent, qualified personnel.

TROUBLESHOOTING

POSSIBLE CAUSE
Mains power failure.
Magnetothermal switch
tion.
Card protection fuse (F1-F2) blown.
Inverter fuse (F4) blown.
Inverter protection activated.
Emergency
devices
(display shows "Err".)
Safety thermostat activated.
Thermostat
probe
display shows "Er1" for the right,
"Er3" for the left.
Thermostat probe in short circuit:
display shows "Er2" for the right,
"Er4" for the left.
Measured temperature difference
between
right
and
higher than 40°C.
Left side plate
Check if supply terminals are live.
interven-
Check dispersion toward earth.
Replace fuse and check for cause.
Replace fuse and check for cause.
Check error message on inverter
display.
activated
Disactivate the emergency device
and press the pedal.
Reset the safety thermostat using
the relative push button.
disconnected:
Check probes connection.
Use properly the whole ironing sur-
left
probes
face.
REMEDY