Cleaning the filter pump (D3)
Undo the four screws from the pump housing, pull the pump housing off including the O ring, and remove the impeller
unit. Clean the pump housing and the impeller unit using clear water and a brush. Reassemble in the reverse order
once cleaning is completed.
Cleaning the UVC clarifying unit (D4-D6)
Keep the indexing lever at the unit head of the UVC unit pressed (D3), turn the water housing counter-clockwise
against the stop and carefully remove. Undo the fixing screw at the clamping screw (D4) and unscrew the latter
counter-clockwise, then pull off the quartz glass including the O ring forward by exerting a slight turning movement
(D5), and remove the O ring from the quartz glass. Clean all components, check for damage and replace, if necessary.
UVC lamp replacement (D7, D8)
Change the UVC lamp after approx. 8000 operating hours. Pull out and replace the UVC lamp.
Important! Only use lamps the identification and capacity data of which correspond to the information on the type plate.
UVC pump unit assembly
Push the O ring on the quartz glass, insert the quartz glass in the unit head against the stop (D9). Press the O ring into
the gap between unit head and quartz glass. Screw on the clamping screw clockwise against the stop and lock with the
fixing screw (D10). Check the O ring sealing the water housing for damage (D11). Place the O ring in front of the
recess at the unit head (D11). Carefully push the unit head into the housing while applying slight pressure. Ensure that
the tenons at the water housing engage in the grooves of the bayonet closure. Turn the unit head clockwise while
exerting slight pressure until the indexing lever engages (D11). Screw the filter pump to the water housing (D2). Insert
the UVC pump unit into the holder in the container wall (A8), refit screen basket and cover (A9), lead the power cable
through the recess in the container edge (A9), and open the skimmer flap. Plug in the mains plug as soon as the unit is
filled with water again (B1).
Pos: 33 /Filter/Filtoskim/Lagern Filtoskim @ 1\mod_1133782756130_121.doc @ 10100
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8° C or, at the latest, when freezing temperatures are to be
expected. Drain and thoroughly clean the unit, check for damage. Remove all foam filters and the UVC pump unit and
clean under clear running water. Store the foam filters at a dry and frost free location, store the UVC pump unit frost
free and immersed in a container filled with water. Do not immerse the power plug in the water! Ensure that the storage
place is inaccessible to children. Close the inlet opening with the frost protection plate supplied and screw the enclosed
screw cap including seal onto the drain socket (winter set) instead of the drain elbow (C8). Cover the filter container
such that the ingress of rain water is excluded.
Pos: 34 /Alle Produkte/Entsorgung mit UVC @ 2\mod_1137146293332_121.doc @ 13332
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special disposal. Ask your
specialist dealer.
Pos: 35 /Filter/Filtoskim/Verschleißteile Filtoskim @ 1\mod_1133782539075_121.doc @ 9900

Wearing parts

The UVC lamp, the quartz glass, the foam filters and the impeller vanes are wear parts and are excluded from the
warranty.
Pos: 36 /Filter/Filtoskim/Störung Filtoskim @ 1\mod_1133782703488_121.doc @ 10075
Malfunctions
Malfunction
The unit does not reach the desired perform-
ance
UVC lamp does not light up
No water outlet from the pond inlet
Pos: 37 /Alle Produkte/Länderkennzeichen/03===F=== @ 0\mod_1126476126844_0.doc @ 4432
Cause
Unit has been in operation only for a short time
Water extremely soiled
Excessive fish and animal population
Foam filters soiled
UVC lamp capacity exhausted
Quartz glass tube soiled
Plug not connected
UVC lamp defective
Power cable of the UVC pump unit defective
UVC overheated
Plug not connected
Pump impeller vanes blocked
Pond inlet blocked
- GB -
Remedy
The complete biological cleaning effect is
only achieved after several weeks
Use the OASE Biokick biological starter for a
fast growth of filter bacteria
Remove algae and leaves from the pond,
perform a partial water change
Guide value: approx. 60 cm fish length in 1 m³
pond water
Cleaning foam filters
Replace the lamp after approx. 8000 operating
hours
Remove UVC and clean quartz glass
Connect plug
Replacing the UVC lamp
Replace the UVC pump unit. Do not repair the
power cable!
UVC automatically switches on when cooled
down
Connect plug
Clean pump
Clean pond inlet
9

Werbung

Inhaltsverzeichnis
loading