Safety information

OASE has manufactured this unit according to the current state of the art and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accor-
dance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recog-
nise possible danger or who are not familiar with these operating instructions, are not permitted to use the
unit!
Pos: 29 /Filter/Filtoskim/Die Kombination von Wasser und Elek. Filtoskim @ 1\mod_1133782453978_121.doc @ 9800
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected or
misused. Do not operate the unit if persons are in the water! Prior to reaching into the water, always disconnect the
power supply to all units used in the water. Compare the electrical values of the power supply with those on the type
plate on the packaging or on the unit itself. Only operate the unit when plugged into an earthed socket. The latter must
have been installed in accordance with the valid national regulations. Ensure that the protective earth wire is led to the
unit. Only use electrical equipment, adapters, extension or connection cables with an earthed contact which are
approved for outside use! The cross section of power connection cables must not be smaller than the rubber cables
identified with H05 RNF. Extension cables must meet DIN VDE 0620. Ensure that the unit is fused for a rated residual
current of max. 30 mA via a residual current-operating system (FI or RCD resp.). Keep the power plug and all connec-
tion points dry! Protect the connection cable when burying to avoid damage. Electrical installations at garden ponds
must meet the international and national regulations valid for installers. Do not carry or pull the unit by the connection
cable! Never operate the unit if the cable or housing are defective! The power connection cable of this unit cannot be
replaced. If the cable is damaged, the entire unit has to be disposed of. Always disconnect the power supply of all units
located in water and of this unit prior to performing work on the unit! Never open the unit or its component parts, unless
this is explicitly mentioned in the operating instructions. Never carry out technical changes to the unit. Only use spare
parts meeting the quoted specifications and original accessories. Only allow authorised customer service outlets to
perform repairs. For your own safety, consult a qualified electrician if you have questions or encounter problems!
Attention! Dangerous ultra-violet radiation.
The radiation of the UVC lamp, even in small doses, is dangerous for eyes and skin! Never operate the UVC lamp in a
defective housing or outside of the housing.
Pos: 30 /Filter/Filtoskim/Montage und Aufstellen Filtoskim @ 3\mod_1141128968211_121.doc @ 15333
Assembly and installation (A)
Fit and adjust the unit according to figures A1-A9. Bury the container at the pond edge in a horizontal position making
sure that the pond water level is in the centre of the skimmer opening.
Pos: 31 /Filter/Filtoskim/Inbetriebnahme Filtoskim @ 1\mod_1133782495995_121.doc @ 9850
Start-up (B)
Attention! Never operate the unit without water flowing through!
Adhere to the safety information given above! Fill the pond with water and wait until the unit is filled with water. Con-
nect the power supply (B1). Note: After a new installation, the unit only reaches its full biological cleaning effect after a
few weeks. The full effect on bacteria is only reached as from an operating temperature of + 10°C. Note: In the event of
overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp automatically
switches on again once cooled down. The unit is switched off by pulling the mains plug (B2).
Pos: 32 /Filter/Filtoskim/Reinigung Filtoskim @ 1\mod_1133782563764_121.doc @ 9950

Maintenance and cleaning

Attention! Always disconnect the power supply prior to starting cleaning and maintenance work!
Adhere to the safety information given above! Check and clean the water outlet into the pond at regular intervals. Only
clean the filter when required, do not use chemical cleaning agents to permit the filter biology to optimally develop,
knowing that cleaning agents kill the bacteria in the foam filters. Open the unit cover, close the skimmer flap (C1) and
pump out the container. The non-return valve in the outfeed socket prevents the pond water from flowing back through
the outlet. Switch the pump off by pulling the mains plug (B2). Remove and empty the screen basket.
Cleaning with the cleaning injector (C2-C3)
Take the cleaning injector out of the screen basket handle and pull the lance out of the foam filter. Fit the lance and
connect the dirt water hose and the clean water hose (water supply) to the cleaning injector (C2). Start the water
supply (recommendation: 1 bar water pressure). Push the lance through the vertical grooves of the blue foam filters
and down to the container bottom (C3). The sludge at the unit bottom is sucked up by the vacuum and removed to-
gether with the outflowing water. Following cleaning, dismantle the cleaning injector and store the components at the
positions provided for this purpose.
Clean and replace foam filters (C4-C7)
Only clean or replace the foam filters if heavily soiled. Note: The bacteria in the filter sludge have an additional biologi-
cal filtering effect. Pull out the filter basket (C4), remove the foam filters, and clean under clean water by vigorously
squeezing (C5). Install the foam filters in the reverse order (C6-C7).
Cleaning the UVC pump unit (D1, D2)
Adhere to the safety information given above! Remove the cover of the UVC pump unit and lift the UVC pump unit out
of the holder in the container wall (D1). Undo the union nut that connects the pump housing to the water housing of the
UVC clarifying unit (D2).