Herunterladen Inhalt Inhalt Diese Seite drucken

Industrial Scientific 17154524-1 Bedienungsanleitung Seite 5

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

The EC type examination certificate is DEMKO 12 ATEX 1204290 with marking code Ex ia I Ma and Ex ia IIC T4 Ga for equipment group and category II
1
1G and I M1.
The model Ventis Slide-on Pump (VSP) complies with relevant provisions of European ATEX directive 94/9/EC and EMC directive 2004/108/EC.
1
The VSP is constructed with reference to published standards of directive 2006/95/EC, to eliminate electrical risks and fulfill 1.2.7 of ANNEX II of
1
directive 94/9/EC.
The VSP is CSA certified according to the applicable CSA standards for use in Class I, Division 1 and Class I, Zone 0 hazardous locations within an
2
ambient temperature range of Tamb: -20°C to +50°C.
The IECEx examination certificate is IECEx UL 12.0021 with marking code Ex ia IIC T4 Ga for hazardous locations with an ambient temperature range of
3
Tamb: -20°C ≤ Ta ≤ +50°C.
The charging contact parameters are: Um = 6.2V; Ii = 1.3A.
3
Introduction
3