Teach in
Standard Setting (for light-on switching only):
Light-on means the sensor's output is active as soon as
the object is detected. Background and foreground are
excluded.
1. Position the object you wish to detect.
2. Press and hold down the SET button until the
bicoloured LED goes out.
3. Release the SET button and wait for the bicoloured
LED to turn green. The sensor is now ready.
Fine setting (for light-on or dark-on switching):
The fine setting is used to teach the detection range over
which the object is supposed to be sensed. The sensor
learns the shortest and longest distance to the object
(lower and upper limit).
Light-on and dark-on require different calibration
procedures.
A. Calibration procedure for light-on:
1. Position the object you wish to detect at the nearest
operating distance (Fig. 4).
2. Press and hold down the SET button until the
bicoloured LED flashes green.
3. Release the SET button.
4. Position the object you wish to detect at the farest
operating distance (Fig. 4).
5. Press and hold down the SET button until the
bicoloured LED goes out.
6. Release the SET button. The sensor is now ready.
B. Calibration procedure for dark-on:
1. Position the object you wish to detect at the farest
operating distance (Fig. 4).
2. Press and hold down the SET button until the
bicoloured LED flashes green.
3. Release the SET button
4. Position the object you wish to detect at the nearest
operating distance (Fig. 4).
5. Press and hold down the SET button until the
bicoloured LED goes out.
6. Release the SET button. The sensor is now ready.
Fig. 4: Teaching the object detection area
Technical Data
Optical data
Operating distance
Output function
Emission type
Electrical data
Operating voltage U
B
Ripple
Current consumption
(output current excluded)
Switching output
Output current
Voltage drop
Reverse polarity protected
Short circuit protected
Switching frequency
Sensitivity setting
Protection class
Mechanical data
Connection type
Housing material
Active surface material
Laser protection class
DIN EN 60825-1/94
Vibration
Shock
Dimensions
Weight
Time data
Turn-on delay
Display
Ready/Error
Output function
Ambient data
Mechanical protection
Permissible ambient light
Operating temperature
Storage temperature
Approvals
Listed 81U2 IND.CONT.EQ for
use in the secondary of a class
2 source of supply
70...200 mm
light on or dark on
red 670 nm
10...30 V DC
2 Vpp max.
50 mA max.
PNP or NPN;
N.O. or N.C.
100 mA max.
≤ 2 V
yes
yes
1 kHz
push-button
2
M12, 4 pole connector
GD-Zn, nickel plated
PMMA
I
55 Hz, 1 mm amplitude
30 g, 11 ms
50 x 42.5 x 15 mm
80 g.
500 µs
Bi-color LED (green/red)
yellow LED
IP67
according to
EN 60947-5-2
-10 ... 50 °C
-20 ... 70 °C
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Phone +49 (0) 71 58/1 73-0
Fax +49 (0) 71 58/50 10
E-Mail: balluff@balluff.de
www.balluff.com