5.3 Representation Preset
Voltage output
Current output
6. Accessory connector
Straight mating connector (5-pol.)
5-pole connector available from SIKO as accessory
art. no. 84109. Wire cross section is max. 0,75 mm².
Cable channel: 6-8 mm.
Please proceed as follows (fig. 2):
1. Mount seal to screen ring (4).
2. Slip parts 1 to 6 over outer cable.
3. Strip cable sheath, isolate conductor.
4. Shorten and turn down screen.
5. Clamp wires into socket (7) (follow connection
diagram).
6. Mount parts 2 ... 6. Place screen around screen
ring (4).
7. Screw pressure screw (1) on coupling sleeve (5).
AH36M
Datum 29.11.2011
Revolu-
Fig. 2: Straight mating connector
tions
Right angle mating connector (5 pole)
5 pole connector Available from SIKO as accessory
art. no. 83006. Wire cross section is to be at least
0,14 mm², max. 0,5 mm². Cable channel: 4-8 mm.
Please proceed as follows (fig. 3):
1. Thread pressure nut onto the cable.
2. Strip the cable sheath, shorten the screen.
3. Bare cores.
4. Thread cores through the housing and connect.
5. Screw housing on pin body.
6. Tighten pressure nut.
Revolu-
tions
Fig. 3: Right angle mating connector
Changing the angle position (fig. 3):
1. Turn on female contact, slightly pull out and rotate
to desired angular position (in steps of 45°).
2. Screw on female contact.
Attention! Multiple angle adjustments to a single
direction cause shortening of the line and break.
Art.Nr. 85966
Änd. Stand 452/11
7