2.1.3 Removing the cartridge
1. Press the release lever and, at the same time, pull the
piston rod back as far as it will go.
2. Grip the cartridge at the mixing nozzle and lift it upwards
out of the dispenser.
-NOTE-
Partly used Hilti HFX anchor adhesive cartridges should
en
be stored with the mixing nozzle screwed on. The
remaining contents of the cartridge should be used
up within four weeks.
The applicable storage conditions must be observed
during this period.

3. Cleaning and maintenance

Fresh mortar adhering to functional parts of the dis-
penser (inside and outside) should be removed imme-
diately with a cleaning cloth.
Hardened adhesive mortar can be removed only by
mechanical means.
Do not expose the piston rod to excessive dust and
lubricate it with a little oil at regular intervals.

4. Warranty

Hilti warrants that the product supplied is free of defects
in material and workmanship. This warranty is valid as
long as the product is operated and handled correctly,
cleaned and serviced properly and in accordance with
the Hilti operating instructions, all warranty claims are
made within 12 months (unless other mandatory national
regulations prescribe a longer minimum period) from
the date of sale (invoice date) and the technical system
is maintained, i.e. only original Hilti consumables, acces-
sories and spare parts are used with the product.This
warranty provides the free-of-charge repair or replace-
ment of defective parts only. Parts requiring repair or
replacement as a result of normal wear and tear are not
covered by this warranty.

5. EC declaration of conformity

Designation:
Type:
Year of design:
4
Printed: 07.07.2013 | Doc-Nr: PUB / 5103002 / 000 / 00
When the cartridge is reused, a new mixing nozzle
must be screwed on and the initial portions of adhe-
sive dispensed must be discarded until the mixture
escaping from the mixing nozzle has a uniform grey
color.
2.2 Using the Hilti MD 300 with other single-
component cartridges of the same form
If the Hilti MD 300 is used in conjunction with other
single-component cartridges of the same size and
form, the dispenser must be used in accordance with
the instructions provided with the applicable cartridge.
Additional claims are excluded, unless mandatory
national regulations prohibit such exclusion. In par-
ticular, Hilti is not obligated for direct, indirect, inci-
dental or consequential damages, losses or expenses
in connection with, or by reason of, the use of, or inabil-
ity to use the product for any purpose. Implied war-
ranties of merchantability or fitness for a particular
purpose are specifically excluded.
Send the product and/or related parts immediately upon
discovery of a defect to the local Hilti marketing organi-
zation for repair or replacement.
This constitutes Hilti's entire obligation with regard to
warranty and supersedes all prior or contemporaneous
comments and oral or written agreements concerning
warranties.
We declare, on our sole responsibility, that this prod-
Dispenser
uct complies with the following standards or standard-
Hilti MD 300
ization documents: 98/37/EG
2004