Herunterladen Diese Seite drucken

CME Smart charger Anleitung Seite 5

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Trouble shooting and service
Yellow flashing LED
Yellow and Green simultaneus
flashing
Yellow and green alternate
flashing
Standard setting -free ventilated / valve regulated with parallell consumption ,
Free ventilated, open lead acid
Charging phase Voltage level
I1-fas
>1,4V/cell
U1-fas
2,4V/cell
U2-fas
2,3V/cell
Traction batteries
Free ventilated, open lead acid
Charging phase Voltage level
I1-fas
>1,4V/cell
U1-fas
2,4V/cell
I2-fas
max 2,8V/cell min 1h max 4h
U2-fas
2,26V/cell
Technical data
Measurements:
Weight:
Ambient Temperature:
Mains Voltage:
Power Factor:
Rated Voltage/Current:
Secondary Cables:
Protection:
General:
Charging algorithms
The Smart charger charger is designed for freely ventilated and valve regulated batteries. All chargers are
equipped with app. charging curves.
When CME is informed of battery capacity and type the charger will be delivered with the correct setting.
If you change to another type or size of battery, please contact CME for change of charging algorithm.
www.cmelux.fi
CME-Lux Oy, Finlanaysoninkuja 9, FIN 33210 Tampere
may mean that the battery is not properly connected.
Check cables, connection terminals, plugs and other connections to the
battery. Measure the voltage at the battery and at the charger.
The charging voltage is low <1,8V/cell
Internal temperature is to high
If the connecting points and the voltage is correct, contact CME for
consultation.
Valve regulated, Gel / AGM /Orbital
Time
Voltage level
max 12 h
>1,4V/cell
max 12 h
2,35V/cell
unlimited
2,3V/cell
Valve regulated, Gel / AGM / Orbital
Time
Voltage level
max 12h
>1,4V / cell
max 5h
2,35V/cell
max 2,6V/cell
unlimited
2,26V/cell
80x155x43
0,8Kg
-25 °C - +40 °C
170 Volt - 275 Volt AC, 45 Hz - 400 Hz (<200V will mean limited effect)
~1
12V/6A, 24V/3A
2
1,5 m x 1,5 mm
1, IP 65
Protected against wrong polarity and short circuit
This charger can be used as a voltage supply. (Special program)
e5, CE-certified in accordance with valid EN-standards.
Time
max 12 h
max 12 h
unlimited
Time
max 12 h
max 7 h
min 1h max 4h
unlimited
5

Werbung

loading