Herunterladen Diese Seite drucken

Sentiotec FTS2 Montage Seite 2

Feuchte- temperatursensor
Verfügbare Sprachen

Verfügbare Sprachen

HUMIDITY- TEMPERATURE SENSOR FTS2
Installation may only be performed by a qualified electrician
or similarly qualified person.
1. Arrangement:
150 mm
Heater sensor F1 in
the area above the
heating system
Heating system
Evaporator
2. Installation:
1. Step:
Drill a hole Ø 30 - 40 mm in the
middle of a cabin wall panel.
Keep 150 mm distance to the
ceiling.
3. Connection:
Pro B3, Pro C3, Pro D3(i), just sauna combi
OSG STB F1
Version 12/18
193
150 mm
Humidity- Temperature
sensor FTS2
2. Step:
Pull the connecting line (5-wire) coming from
the control unit through the hole from the outer
side of the cabin. Connect the wires with the
clamps, put it back through the hole and fix the
sensor case.
2 wood screws 4 x 16
Sauna control home.com4
red
orange
green
red
orange
green
40 - 100 mm
black
brown
1-043-927
EN
loading