ME 3120 RC
6. Hold "Down" to enter into RCC receiving mode
7. Under RCC receiving status, click "Down" to exit the RCC receiving state
8. when ALARM rings, click "snooze" to enter into the snooze state every 5 minutes
9. press "CH" to switch RF channel, CH1 àCH2àCH3
10. hold "CH" key for 2 seconds to clear out all data of current "Channel"
3.3 Time set
1. hold "Set" key for 2 seconds to enter into time setting
2. the sequence of time setting: Year(2000-2099) àMonthà Date à Language à Hour à Minute à Time zone àExit
3. there will have 1Hz flashing during setting
4. press "Set" to confirm the setting, and enter the next setting state
5. press "Up" one time, the setting will go ahead for one step; hold the key for 2 seconds, it will run forward by 8 steps/
second.
6. press "Down" one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. moon phase is changed accordingly
8. the system will exit automatically if no key is operated in 8 seconds.
3.4 Alarm set
1. hold "Alarm" key for 2 second to enter into alarm setting
2. the sequence of alarm setting: Hour à Minute à exit
3. there will have 1Hz flashing during setting
4. press "Alarm" to confirm the setting, and enter the next setting state
5. press "Up" one time, the setting will go ahead for one step; hold the keys for 2 seconds, it will run forward by 8 steps/
seconds.
6. press "Down" one time, the setting will backward for one step; hold for 2 seconds, it will run back by 8 steps/second.
7. the system will exit automatically if no key is operated in 8 seconds.
8. at normal status, press "Alarm" to turn on/off alarm function.
4 Function and effect
4.1 The receiving function of RF
1. after installing the battery and checking temperature/humidity, it will enter RF receiving state automatically for 3 minutes.
2. under normal display mode, hold the "CH" key for 2 seconds to clear out the channel information
3. if there is no effective signal with same ID code received for the current channel in 35 minutes, the temperature of that
CH will shows "--.-".
4. the temperature display will resume back when the correct signal is received again.
4.2 The function of RCC receiving
1. Conditions of entering RCC receiving status:
a. Power on or reset to enter RCC receiving status
b. Entering RCC receiving status at 2:00,3:00,4:00,5:00 automatically
c. Press "DOWN" for 2 seconds to enter RCC receiving status forcedly
2. The time for RCC receiving is 7 minutes
3. The displaying of icons during receiving:
a. When it enters RCC receiving status, the tower-shaped part of RCC symbol on the LCD will flash in the frequency of
1 Hz.
b. When it is receiving the signal, the tower-shaped part of RCC symbol will be still, while thesymbol of RCC will flash
in the frequency of 1 Hz.
4. When it receives the signal successfully, the whole RCC icons will be ON, and exit the receiving status.
5. When it is receiving signals, press "Down" or "UP" key, it will exit RCC receiving status, pressing any other key will have
no effect.
6. During the 4 times of auto receiving everyday, if it received signal once, it will not enter the receiving status automatically
until 2:00 next day.
6