Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - Gima TOBI CLINIC Handbuch

Absaugpumpen
Vorschau ausblenden Andere Handbücher für TOBI CLINIC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
specification of NOT REPAIRED INSTRUMENT, accompanied by an explanation letter.
GIMA will decide if contamination is due to bad functioning or misuse. If contamination is due to bad functioning, GIMA will substitute the instrument,
only if a SALE RECEIPT and STAMPED GUARANTEE accompany the same.
GIMA is not responsible for contaminated accessories, they will be substitute at customer's expenses.
For this reason it is COMPULSORY to carefully disinfect the external part of the instrument and accessories with a cloth soaked in methylated spirits
or hypochlorite-based solutions. Put the instrument and accessories in a bag with indication of disinfecting. We also request to specify the kind of
fault, in order to speed up repairing procedures.
To this end, please read the instructions carefully in order to avoid damaging the equipment through improper use.
Always specify the fault encountered so that GIMA can establish whether it falls into the category of the faults covered by the guarantee.
The TOBI CLINIC suction equipment does not need maintenance or lubrication.
It is necessary to check functioning and instrument before every use.
Unpack the instrument and always check integrity of plastic parts and feeding cable, they might have been damaged during previous use.
Always check the integrity of the footswitch power cord. Connect cable to electrical network and turn switch on.
Close the aspiration outlet with your finger and with suction regulator in maximum vacuum position check that the vacuum indicators reaches -90
kPa (-0.90 bar) maximum. Rotate the knob from right to left and check the aspiration regulating control.
The vacuum indicator should go down -40 kPa (-0.40 bar). Verify that loud noises are not present, these can indicate wrong functioning.
A protection fuse (F 1 x 4A L 250V) reachable from exterior and it situated in the plug protects the instrument. For use replacing, always check the
type and the range indicated.
Fault type
1. The suction unit doesn't
work
2. No aspiration
3. No aspiration
4. The Vacuum power on the
patient side is either very
low or absent
5. The float doesn't close
6. The float doesn't close
7. Low suction
Faults 1 - 2 - 3 - 4 - 5 - 6 - 7
If the overfill security system it's activated, don't proceede with the liquid aspiration.
If the overfill security system doesn't work there are two cases:
1° case – If the overfill security system doesn't work the aspiration will be stopped by the bacteriological filter who avoid the liquid penetration
inside the device.
2° case – If both the security system doesn't work, there is the possibility that liquid comes inside the device, in this case return the device to
GIMA SpA technical service.
The manufacturer will provide upon request electric diagrams, components list, descriptions, setting instructions and any other
information that can help the technical assistance staff for product repair.
BEFORE EVERY CHECKING OPERATION, IN CASE OF ANOMALIES OR BAD FUNCTIONING, PLEASE CONTACT GIMA TECHNICAL
SERVICE.
GIMA SpA DOES NOT GIVE GUARANTEE IF INSTRUMENT, AFTER THE TECHNICAL SERVICE CHECKING, APPEARS TO BE
TAMPERED.
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC:
In respect of art. 13 Decreto Legislativo 25 Luglio 2005, n.151 "Actuation of European directives 2002/95/EC, 2002/96/EC and 2003/108/EC, for
reduction in use of dangerous substances in the electric and electronic device and for garbage disposal"
The symbol as over applied on the device or its packaging means that at the end of its useful life the product must not be disposed of with domestic
waste. At the end of device useful, the user will must deliver it to the able collecting centres for electric and electronic garbage, or give back to the
Cause
Cable is damaged
External power source failure
Jar Cap badly screwed down
Lid seal not in its seat
a) Vacuum regulator set to minimum
b) Protection filter blocked or
damaged
c) Connection tubes blocked, kinked
or disconnected
d) Shut-off valve blocked or damaged
e) Pump motor damaged
If the cap has been washed, ensure
that the float is not partially detached
The float it's covered by dirty material
Foam inside the jar
None of the remedies has achieved
the desired results

MAINTENANCE

Replace the cable
Check the external power source
Unscrewed the cap, then rescrew it correctly
Unscrew the cap and insert the seal properly in its seat
a) Turn the vacuum regulator clockwise and check the value of the
vacuum on the gauge
b) Replace the filter
c) Replace or reconnect the tubes, check the jar connections
d) Empty the jar, or disconnect the tube from the jar and unblock the
shut-off valve. The unit twill only work in the upright position
e) Refer to authorised service personnel
Insert the float into it's place
Unscrewed the cap, leave the and put in on autoclave
Fill the jar to 1/3 full of ordinary water
Contact the seller or GIMA After-sales Assistance Service
15
Solution

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis