Narvi Oy
EN 15821:2010
Multi- ring sauna stoves red by natural wood logs
for space heating in residential buildings
Narvi NC16
Fire safety (initiation, risk to adjacent
elements)
- including declared safety
distances to combustible
materials:
Emission of combustible products
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy e ciency, as:
- carbon monoxide emission at 13 % O
- total e ciency
- ue draught
- thermal output
(i.e. nominal space heating output)
- refuelling loads
Durability
Narvi Oy
EN 15821:2010
Multi- ring sauna stoves red by natural wood logs
for space heating in residential buildings
Narvi NC20
Fire safety (initiation, risk to adjacent
elements)
- including declared safety
distances to combustible
materials:
Emission of combustible products
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy e ciency, as:
- carbon monoxide emission at 13 % O
- total e ciency
- ue draught
- thermal output
(i.e. nominal space heating output)
- refuelling loads
Durability
DE
12
12
Pass
Back
150 mm
Side
150 mm
Ceiling
1 250 mm
Pass
Pass
NPD
Pass
387 C
Pass
Pass (0,07 %)
Pass (70 %)
12 Pa
16 kW
7 kg
Pass
12
Pass
Back
150 mm
Side
150 mm
Ceiling
1 200 mm
Pass
Pass
NPD
Pass
425 C
Pass
Pass (0,12 %)
Pass (67 %)
12 Pa
16 kW
9 kg
Pass
Narvi Oy
12
EN 15821:2010
Multi- ring sauna stoves red by natural wood logs
for space heating in residential buildings
Narvi NC20 VS
Fire safety (initiation, risk to adjacent
elements)
- including declared safety
distances to combustible
materials:
Emission of combustible products
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy e ciency, as:
- carbon monoxide emission at 13 % O
- total e ciency
- ue draught
- thermal output
(i.e. nominal space heating output)
- refuelling loads
Durability
Narvi Oy
12
EN 15821:2010
Multi- ring sauna stoves red by natural wood logs
for space heating in residential buildings
Narvi NC24
Fire safety (initiation, risk to adjacent
elements)
- including declared safety
distances to combustible
materials:
Ceiling
Emission of combustible products
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy e ciency, as:
- carbon monoxide emission at 13 % O
- total e ciency
- ue draught
- thermal output
(i.e. nominal space heating output)
- refuelling loads
Durability
Yrittäjäntie 14, FI-27230 Lappi • tel. +358 0207 416 740 • fax +358 0207 416 743 • www.narvi.fi
Pass
Back
150 mm
Side
150 mm
Ceiling
1 200 mm
Pass
Pass
NPD
Pass
425 C
Pass
Pass (0,12 %)
Pass (67 %)
12 Pa
16 kW
9 kg
Pass
Pass
Back
150 mm
Side
150 mm
1 200 mm
Pass
Pass
NPD
Pass
463 C
Pass
Pass (0,17 %)
Pass (65 %)
12 Pa
17 kW
11 kg
Pass