Starting the DDH 20-1
Before plugging the device on mains
power, check that the DDH 20-1 is turned off
(switch on the back).
Place the humidifier on a flat surface.
Use only the provided AC adpator.
Connect the AC adaptor to the DDH 20-1
with the socket on the back.
Plug the cord in an electrical socket and
turn the device on.
The DDH 20-1 dehumidifier is now ready
to use.
Operating instructions
The green light means that the device
works properly.
The red light means that the tank is full.
Continuous drainage: connect one side
of the provided hose to the tank (⑥) and
the other side to a sewage such as sink
or flush.
Tank drainage
Unplug the device.
Remove the tank and empty it after
having pulled the cover off.
Replace the tank.
The DDH 20-1 is now ready to work again.
The DDH 20-1 automatically stops when
the tank is full.
The Peltier Effect principle
The DDH 20-1 dehumidifier works by Peltier Effect, invented by the french physisist Jean-Charles
Peltier, based on a thermo-electrical principle. The moisture level is very sensitive to temperature
variations. The Peltier effect creates a gap in temperature, that removes humidity from the air.
As the DDH 20-1 does not use any compressor, it is environment friendly.
Maintenance
Daily maintenance
Before any operation, unplug the device.
Empty the water from the tank and rinse
off with clear water in order to remove
any eventual scale deposit.
Dry the tank with absorbant tissue.
Weekly maintenance
Check if the back vent is not dusty. If
needed, clean it with a dry brush or a
vacuum.
Caution
Check that the housing is not swamped.
Do not use solvents or abrasive products
when cleaning the device.
Storage
Clean as previously recommended with a
white vinegar-based solution.
Let the device dry.
Store in a dry place, preferably in its original
packaging. Avoid high temperatures.
The product does not work properly
Check if the plug is properly installed on
the mains and on the device.
Check if the mains outlet is working.
Check if the tank is well placed in the
device.
Do not open the device. Contact the
retailer for an expert assesment.