IV. SECURITY MATTERS:
1. Please do no operate the inverter while you hand is wet, Keep it away from the touch of
children.
2. The temperature of the shell will be high after longtime working, so do not touch it in case of
scalded
3. Do not put metal into the inverter in case of not to electric shock.
4. Do not touch the metal of the socket while insert the plug to the socket of the inverter.
5. Keep the inverter away from explosives.
6. Keep all AC electricity away from the inverter, it will damage the inverter and also may cause
electric shock.
V. PROTECT FUNCTION AND RESTART WORK METHOD:
Function
LED light
Input low voltage
Green on Red
alarm
off
Input low voltage
Green on Red
shut down
on
Input over
Green on Red
voltage shut
on
down
Over load
Green on Red
protection
on
Over
Green on Red
temperature shut
on
down
Output short
Green on Red
circuit
off
(PS: If with USB port, the USB port can work normally under all kinds of protection condition.)
VI. WASTE DISPOSE:
Please do not discard the products when it is useless, otherwise it will cause pollution to the
environment.
Owner's manual
State description
Alarm
AC output
Alarm
AC have
output
No Alarm
No AC
output
No Alarm
No AC
output
No Alarm
No AC
output
Alarm
No AC
output
No Alarm
No AC
output
Restart work method
When the voltage of battery
return to related range, alarm
stop automatically.
When the voltage of the
battery return to related range,
the inverter will restart work,
green light on, red light off,
When the voltage of the
battery return to related range,
the inverter will restart work,
green light on, red light off
Reduce the load to related
range, the inverter will restart
work, green light on, red light
off.
When the inside temperature
return to related range,
inverter will restart to work,
green light on, red light off.
When short circuit stopped,
inverter restart to work
automatically.
EN
9