Herunterladen Inhalt Inhalt Diese Seite drucken

Sun Hydraulics XMD-01 Installationsanleitung Seite 4

Elektrohydraulischer verstärker
Vorschau ausblenden Andere Handbücher für XMD-01:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operational Specifications Continued
Inputs
Universal
XMD-01
Inputs
(1 universal input)
XMD-02
(2 universal inputs)
Input Range
Current Input Mode: 0 to +20 mA. Maximum allowable
current: +22 mA (impedance Z = ~200 Ω). Active circuit
protection above 22 mA and limited to 32 V. Digital Input: 0
to +Supply, not to exceed 32 Vdc (impedance Z = ~10 kΩ).
Digital Input: Debounce time 200 ms fixed in device
firmware. Maximum voltage on any input pin +32 Vdc and
-0.7 Vdc.
Outputs
PWM Outputs
Current Regulation ± 1mA above 35 mA
PWM Frequency
Dither Frequency
Dither Amplitude
Diagnostics
Flyback Protection
Ramp Time
Reference Output
04
XMD-01
(1 PWM output)
XMD-02
(2 PWM outputs)
33 Hz – 5 kHz
33 Hz – 500 Hz
0 – 25% of PWM Period
Open/short-circuit detection
Integrated
0 – 65 seconds, 1-mS increments
5 Vdc, ±0.1 Vdc (250 mA max.)
© 2017 Sun Hydraulics Corporation
Pub.#999-901-853 November 2017
0 – 5 Vdc, 0 – 10 Vdc, 4-20 mA, digital,
frequency (60 Hz – 10 kHz), PWM
(60 Hz – 10 kHz), resistive
(0 – 100 kΩ), software configurable
0-3.0 Amps Peak -40°C + 75°C
continuous per channel
0-2.7 Amps Peak +75°C + 85°C
continuous per channel
www.sunhydraulics.com

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xmd-02

Inhaltsverzeichnis