HANDY HINT
Testi ng the earth system
a)
Turn the energizer off . At least 40m (130ft ) along the fence line drive a steel
stake into damp soil and connect it to the fence wire.
b)
Turn the energizer on and wait 30 seconds. Check the earth system voltage
using the navigati on keys. The earth voltage should be 0.2 – 0.3KV or less. If
it is higher add earth stakes unti l 0.2-0.3KV is achieved. In dry conditi ons or
areas with low mineral content soil an earth return system may be required as
described in the Gallagher Power Fence™ Manual or visit www.gallagher.co.
Fence Zone Voltage and Alarm
View the Fence Zone performances by pressing the navigati on butt ons (< or >) unti l
the zone indicati on arrow is highlighti ng the desired fence zone (1 - 6). The fence
zones output voltage and alarm informati on is displayed in the same way as the
Energizer output voltage and alarm informati on. See Energizer Voltage and Alarm
secti on p. 12.
To adjust or turn off the fence zone alarms, see Adjusti ng/Turning Off Alarms secti on
p. 13.

Multi ple Zones in Alarm

In a situati on where multi ple zones are in alarm, one of the zones will be fl ashing.
This is the zone with the greatest increase in current and is most likely the zone with
a serious fault.
14
Gallagher 3E2489 M1800i M2800i Energizer User Manual
Controller showing multi ple zones in alarm