Gallagher 3E2489 M1800i M2800i Energizer User Manual
Current Display
The output current indicates how hard your energizer is working. When your fence
is in good conditi on this reading will be low, typically under 15 Amps. As the load
on the fence increases the current will rise and output voltage will fall. The output
current will typically change with fence conditi ons, seasonal grass growth and wet
weather. A high output current, typically over 40 Amps indicates there is a very high
load or short circuit on the fence.
Voltage Display
Output voltage is an indicati on of how eff ecti ve the shock is on your fence. It is
generally recommended to have 3KV or above on the fence at any ti me. If the output
voltage is too low there will not be enough voltage to 'break' through the animals
hide and deliver an eff ecti ve shock.
Zone Indicators
The zone indicators show what zones are acti ve on the fence system. The Energizer
zone (
) and Earth zone (
installing a combinati on of up to 6 Fence Monitors or Alarm Systems. See Opti onal
Accessories (p.16)
Navigati on Butt ons
The navigati on butt ons allow you to view the performance of diff erent areas of your
fence system. By pressing (<) or (>) you can scroll through the zone indicators to
view fence or earth voltage. The zone you are looking at is highlighted by the zone
indicati on arrow (

Standby Butt on

Pressing the standby butt on turns the energizer pulses on or off .
Setti ngs Butt ons
The setti ngs butt ons allow you to adjust the alarm levels and output voltage of the
energizer. Pressing the setup butt on (
setup mode. If no further butt ons are pressed within 10 seconds the energizer
automati cally exits setup mode and starts pulsing as normal.
Other Icons
The controller may occasionally display other icons for your informati on.
Energizer over-temperature. The energizer has detected that its internal
temperature is too high to operate safely, has automati cally slowed its pulse
rate down and may shut down unti l the temperature has decreased.
Setti ngs mode. The user has entered the controller setup mode.
Standby mode. The energizer has been placed into standby and has stopped
pulsing. Press the standby butt on to resume normal operati on.