Herunterladen Inhalt Inhalt Diese Seite drucken

Dräger FPS-COM 5000 Gebrauchsanweisung Seite 25

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Fault
Cause
Mechanics
Battery compartment
Screw not completely
cannot be closed/
loosened
opened
Communication unit
No fixing lugs/
cannot be fitted/
defective fixing lugs
dismantled
on visor frame of
mask
Fastening eyes on
communication unit
faulty
Communication unit
not properly hooked
onto connector
Earphone cannot be
Earphone deformed
bent to desired
or gooseneck faulty
position
Dräger FPS-COM 5000
Remedy
Fault
No connection via
cable to radio
Completely loosen
possible
the screw.
Replace visor frame.
Replace fastening
eyes.
Dismantle
communication unit
and fit again.
Replace earphone.
Troubleshooting
Cause
Remedy
Cable faulty
Replace cable.
Cable not fitted
Check connection
correctly
between cable and
radio. Fit cable again
if necessary.
Check connection
between cable and
communication unit.
Fit cable again if
necessary.
Incorrect cable
Use suitable cable.
connected
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis