4.5
Approvals, conformities, certifications
See operating instructions of the manufacturer of the circulation pump for ver-
sions with circulation pump.
4.6
Technical specifications
Parameter
General specifications
Dimensions with insulation
(W x H x D)
Weight
Material of fittings
Insulation material
System
System pressure
System capacity
System flow rate
Operating temperature range
Medium
Pressure loss
A-AB
B-AB
Product description
180-2 DN 25 RTA 180-3 DN 25 RTA
Observe maximum pressure of circula-
tion pump used.
Flow coefficient
180-2 DN 25 RTA / 180-3 DN 25 RTA
Value
250 x 475 x 153 mm
Approx. 8 kg
Brass
Polypropylene EPP
Max. 10 bar
Max. 50 kW
Max. 2150 l/h
Max. 100 °C
3
Kvs = 4.8 m
/h
Max. 32 kW
Max. 1400 l/h
Flow coefficient
3
Kvsv = 2.94 m
/h
Flow coefficient
3
Kvsv = 2.12 m
/h