Flame sensor
The flame sensor is a photocell that registers the flame and stops combustion if the
flame goes out.
Ventilation
BE CAREFUL:
Risk of air pollution – only use the indirect air heater in well ventilated areas.
Ensure a sufficient supply of fresh air – if using more than one indirect air heater,
there must be an extra air supply.

How to start the indirect air heater

1. Fill the tank with diesel oil.
2. Replace the fuel cap.
3. Plug the cable into a three-pin power outlet with an earth connection.
4. Set the thermostat to the desired setting and switch ON. The indicator light will light up
and the indirect air heater will start.
If the indirect air heater does not start, it may be because the thermostat temperature
is set too low – set it to a higher temperature. If it still does not start, try turning the
power off and on again. Also check the fuse on the circuit board and that the voltage
is correct. See the section Fault codes on page 19.

How to switch off the indirect air heater

Turn the switch to OFF. When the machine has cooled down, you can unplug it.
P. Lindberg A/S
Tel.: +45 70 21 26 26
Indicator lamp
Temperatur
e control
11
Sdr. Ringvej 1
DK-6600 Vejen
Temperature (room
temperature)
ON/OFF
switch
e-mail: salg@p-lindberg.dk
MAN 9058634 EN V1
www.p-lindberg.dk