1-5. INSTALLATION DIAGRAM

Open as a rule
More than 500 mm
if the front and both
sides are open
More than
100 mm
Open as a rule
More than 500 mm if the back,
both sides and top are open
*2 The manufacturing year and month is indicated on the
spec name plate.
Units should be installed by licensed contractor according to local code requirements.

1-6. DRAIN PIPING FOR OUTDOOR UNIT

Please perform the drain piping work only when draining from one place.
1) Provide drain piping before indoor and outdoor piping connection.
2) Connect the soft PVC hose (L) I.D.15 mm as shown in the illustration.
3) Make sure to provide drain piping with a downhill grade for easy drain flow.
Note:
Install the unit horizontally.
Do not use the drain socket (1) in the cold regions. Drain may freeze and it makes
the fan stop.
The outdoor unit produces condensate during the heating operation. Select the instal-
lation place to ensure to prevent the outdoor unit and/or the grounds from being wet
by drain water or damaged by frozen drain water.
En-3
After the leak test, apply insulating
material tightly so that there is
no gap.
When the piping is to be attached
to a wall containing metals (tin
plated) or metal netting, use a
chemically treated wooden piece
20 mm or thicker between the wall
and the piping or wrap 7 to 8 turns
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump down before removing
the old air conditioner. Remake
flare according to the dimension
for new refrigerant.
*2
More than 100 mm
More than 200 mm if there are
obstacles to both sides
More than 350 mm
ACCESSORIES
Check the following parts before installation.
(1) Drain socket
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord*1
(B) Indoor/outdoor unit connecting wire*1
(C) Extension pipe
(D) Wall hole cover
(E) Piping tape
Extension drain hose
(F)
(or soft PVC hose, 15 mm inner
diameter or hard PVC pipe VP16)
(G) Refrigeration oil
(H) Putty
(I) Pipe fixing band
(J) Fixing screw for (I)
(K) Wall hole sleeve
Soft PVC hose, 15 mm inner
(L)
diameter or hard PVC pipe VP16
for drain socket (1)
Note:
*1 Place indoor/outdoor unit connecting wire (B) and
power supply cord (A) at least 1 m away from the
TV antenna wire.
The "Q'ty" for (B) to (K) in the above table is quantity
to be used per indoor unit.
Outdoor unit installation
800
150
500
Air inlet
Air inlet
Air outlet
4-10 × 21 Oval holes
(1) Drain socket
1
1
1
1
1
1
1
Little
amount
1
2 to 7
2 to 7
1
1
(Unit: mm)
(L) Soft PVC hose