Centrad DL07 Bedienungsanleitung Seite 4

Induktivitätsmodul

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Decade
: x1µH
x10µH
Measurement freq. : 5M
1M
Mini Q
: 55
55
Maxi Current
: 0.8A
0.7A
Maxi resistance
: 0.25Ω
0.55Ω
Outputs
:
8 safety sockets (D1 to D8).
Entry
:
1 safety earth socket (D0, female lead).
Condition of use
:
+5°C to +40°C
Condition of storage
:
-10°C to +50°C
Condition of moisture :
see diagram
Safety
:
Meets EN 61010-1standard,
overvoltage category I, pollution 1
Dimensions
:
h = 80mm
Mass
:
1.64Kg ; 1.76Kg packed.
Front panel
:
The assembly is mounted on a front panel, able to be built
in a 19" rack. Its height is 2U, its length is 84F (F=5.08mm).
7.5
208.3
6 x Ø3.5
2-5 Symbols and Definitions
You will find the symbols listed hereafter on the material :
EARTH TERMINAL
Decade
: x1µH
x10µH
Measurement freq. : 5M
1M
Maxi Q
: 55
55
Maxi Current
: 0.8A
0.7A
Maxi resistance
: 0.25Ω
0.55Ω
Outputs
:
8 safety sockets (D1 to D8).
Entry
:
1 safety earth socket (D0, female lead).
Condition of use
:
+5°C to +40°C
Condition of storage
:
-10°C to +50°C
Condition of moisture :
see diagram
Safety
:
Meets EN 61010-1standard,
overvoltage category I, pollution 1
Dimensions
:
h = 80mm
Mass
:
1.64Kg ; 1.76Kg packed.
Front panel
:
The assembly is mounted on a front panel, able to be built
in a 19" rack. Its height is 2U, its length is 84F (F=5.08mm).
7.5
208.3
6 x Ø3.5
2-5 Symbols and Definitions
You will find the symbols listed hereafter on the material :
EARTH TERMINAL
x100µH x1mH
x10mH x0.1H
500K
500K
50K
60
70
100
0.38A
0.14A
70mA
1.8Ω
3.4Ω
12.1Ω
l = 430mm
p = 96mm
411.5
426.4
!
CAUTION !
REFER TO THE MANUAL
x100µH x1mH
x10mH x0.1H
500K
500K
50K
60
70
100
0.38A
0.14A
70mA
1.8Ω
3.4Ω
12.1Ω
l = 430mm
p = 96mm
411.5
426.4
!
CAUTION !
REFER TO THE MANUAL
3.SAFETY INSTRUCTIONS
x1H
50K
16K
Electric overload :
!
100
60
A voltage exceeding the specified range must never be applied.
50mA
40mA
So as not to compromise your safety and ensure good stability, the product
82Ω
420Ω
must be at room temperature at least one hour before use.
Beyond 50V, the safety leads must be used.
In the case of a connection to the ground using the D0 socket, the lead must be
connected first and disconnected last.
The purpose of this connection is to serve as a shield and allow for work with
voltages of up to 250 Volts.
4. AFTER SALES SERVICE
maximum relative
humidity
This device is guaranteed ONE YEAR parts and manpower against all manufacturing
defects. Return expenses are borne by the client.
Only devices returned with a dated purchasing invoice, can be covered by the
guarantee.
Any intervention carried out by unauthorized persons or organizations, shall void the
guarantee.
Satisfied with your acquisition ?
fixed or adjustable laboratory power supplies
AL936N
For more details, go to
x1H
3.SAFETY INSTRUCTIONS
50K
16K
Electric overload :
!
100
60
A voltage exceeding the specified range must never be applied.
50mA
40mA
So as not to compromise your safety and ensure good stability, the product
82Ω
420Ω
must be at room temperature at least one hour before use.
Beyond 50V, the safety leads must be used.
In the case of a connection to the ground using the D0 socket, the lead must be
connected first and disconnected last.
The purpose of this connection is to serve as a shield and allow for work with
voltages of up to 250 Volts.
maximum relative
4. AFTER SALES SERVICE
humidity
This device is guaranteed ONE YEAR parts and manpower against all manufacturing
defects. Return expenses are borne by the client.
Only devices returned with a dated purchasing invoice, can be covered by the
guarantee.
Any intervention carried out by unauthorized persons or organizations, shall void the
guarantee.
Satisfied with your acquisition ?
fixed or adjustable laboratory power supplies
AL936N
For more details, go to
So, you will also be satisfied with :
GF467AF
0.01Hz to 5MHz
:
www.elc.fr
So, you will also be satisfied with :
GF467AF
0.01Hz to 5MHz
:
www.elc.fr
PROTECTED
function generators
PROTECTED
function generators