OPERATIOn

BROADCAST

Device menu
Enter
Mode:
12 Broadcast
Prog
Setting:  
Selection:
 
Finish:
Prog
Factory setting
Mode
Mode: Off
Off, Master, Slave
Note: A system with more than one compact module can be controlled with the one common set of sensors. The modules must be interlinked via
the compact bus (see page 24). The module with the connected sensors must be configured as the first module in the bus and as the master. All
of the following modules are configured as slaves. The sensor data are transmitted via the compact bus every two minutes and every time the
sensor value changes. A mode change reboots the module!
GB-18
Mode
Mode
Mode:
OFF
Enter
Automatic:
Twilight:
Sun 1:
Sun 2:
Sun 3:
Wind :
Setting:
Prog
Selection:
Sensors
external (Ext.): External Sensor data
Internal (Int.): Internal Sensors
Slave
Ext.
Ext.
Ext.
Ext.
Ext.
Ext.
 
Enter
External sensor data (compact bus)
• Automatic
• Wind / Rain
• Twilight
• Sun 1
• Sun 2
• Sun 3
Internal Sensors
Module inputs I30-I35