Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Bissell CLEANVIEW POWERBRUSH 44L6N Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting

Problem
Possible causes
Bladder may be empty.
2-in-1 tank may not be seated
properly.
Pump may have lost prime.
The pump belt may be broken.
Reduced
spray OR
no spray
DirtLifter
The brush belt or pump belt is off
PowerBrush
or broken.
does not turn
ReadyTools dial may be on the
wrong setting.
Poor tool position. (Hand held
attachments only).
Removable nozzle may not be
properly attached.
Cleaner
not picking
up solution
2-in-1 tank lid is not properly
installed.
2-in-1 tank is not properly seated.
2-in-1 tank has picked up
maximum dirty water.
The lint screen may be clogged.
Please do
not return
this product
to the store.
Other maintenance or service not included in the manual should
be performed by an authorized service representative.
Thank you for selecting a BISSELL product.
WARNING
To reduce the risk of electric shock, push power button
off and disconnect plug from electrical outlet before
performing maintenance or troubleshooting checks.
Remedies
Turn power switch OFF; Refill bladder
with clean hot tap water.
Turn power switch OFF; remove tank
and reseat tanks.
Turn power switch OFF; after 1 minute
turn ON and depress spray trigger.
Turn power switch OFF and unplug from the
outlet. To check if a pump belt has broken, you
will need a flat head screwdriver. A. Insert the
blade end into the slot of the belt access door
to release. Examine the belt for breakage. You
should be able to see the pump belt looped
around the motor shaft. If it is broken or missing,
please refer to Replacement Parts on page 14.
A replacement belt may be ordered by calling
BISSELL Consumer Services. Complete installa-
tion instructions will accompany the replacement
belt. B. When replacing belt access door be sure
to line up slots of belt access door with slots in
machine, slide door into place and snap shut.
Refer to Remedy 4 above to check if
brush belt or pump belt is broken.
Set ReadyTools dial to either FLOOR
CLEANING or TOOLS for the cleaning job.
Adjust angle; apply more downward
pressure.
Make sure nozzle is on correctly by
slightly raising front of machine to line
up slots on the base of the machine
with the hooks on nozzle. Attach at
base first and then click nozzle into
place. Refer to image 5 on page 9.
Re-install lid; refer to the image on
page 8.
2-in-1 tank must be firmly seated to
function; remove and reseat 2-in-1 tank.
Empty 2-in-1 tank and refill, refer to
the Operation section.
Clean out lint screen. Refer to page 9.
www.BISSELL.com
13

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis