Technical data

2
Technical data
Standards
Conformity
Approvals
Operating conditions
Climatic conditions
Permissible ambient
operating temperature
Permissible site altitude
Vibration resistance
Degree of protection
Mounting position
Operating conditions
22
CE
UR
Class 3K3 to EN 50178
-10 °C ... +55 °C
Above 45 °C the continuous power P
0 ... 4000 m amsl
Above 1000 m the continuous power P
Acceleration resistant up to 1 g
IP65 (NEMA 250 type 4)
Vertical suspended with connecting cables at the bottom or
horizontal standing with fixing bracket at the bottom
Mean value of regenerative power < permanent power of brake
resistor
Regenerative power during braking time < thermal capacity of brake
resistor
Braking time < 10 % of cycle time (braking time + recovery time)
Low-Voltage Directive
UL508, Industrial Control Equipment,
Underwriter Laboratories (File No.
E232497) for USA and Canada
Without condensation, average
relative humidity 85 %
is to be reduced by 2.5 %/°C
d
is to be reduced by 5 %/1000 m
d
EN50178, IEC61800-5-1 and
Germanischer Lloyd, general conditions
EDKRBS047R DE/EN/FR/ES/IT 4.0