3 Safety Notes

The insertion module corresponds to all rele-
vant directives of the EU and is therefore
marked with
.
G
The module must be installed by skilled
personnel only.
G
The module is suitable for indoor use only.
Protect it against dripping water and splash
water, high air humidity and heat (admissi-
ble ambient temperature range: 0 – 40 °C).
G
Immediately switch off the amplifier con-
taining the module
1. if the module or the amplifier is visibly
damaged,
2. if a defect might have occurred after the
unit was dropped or suffered a similar
accident,
3. if malfunctions occur.
In any case the module (with the amplifier)
must be repaired by skilled personnel.
G
For cleaning only use a dry, soft cloth;
never use water or chemicals.
G
No guarantee claims for the module and no
liability for any resulting personal damage
or material damage will be accepted if the
module is used for other purposes than
originally intended, if it is not correctly in-
stalled or operated, or if it not repaired in an
expert way.
If the module is to be put out of oper-
ation definitively, take it to a local re-
cycling plant for a disposal which is
not harmful to the environment.
4 Installing and
Connecting the Module
WARNING Always disconnect the mains
plug of the amplifier from the
socket before installing the mod-
ule: Risk of electric shock!
1) Unscrew the housing cover of the ampli-
fier.
2) On the front panel of the amplifier, unscrew
the cover plate of the insertion compart-
ment.
Remove the three-pole cable glued to
the cover plate. Insert the module and fas-
ten it. Then connect the cable to the pin
connector AN07 AUDIO (see page 2).
Thus, the module is supplied with 17 V
and the audio signal is sent to the ampli-
fier.
3) To install the connection plate provided
(a), unscrew the corresponding cover
plate on the rear of the amplifier or detach
the corresponding cover plate. Insert the
connection plate into the opening and fas-
ten it with screws.
4) Connect the connection plate to the mod-
ule according to the figure on page 2.
5) Before closing the housing cover of the
amplifier, store an emergency message
(chapter 5.1). A message can only be
stored or deleted via the operating ele-
ments (b – f) on the PCB. This will prevent
inadvertent deletion, for example.
6) For alarm triggering and thus for automatic
replay of the stored emergency message,
connect a corresponding alarm contact
(normally open contact) to the alarm input
E/M of the connection plate (a).
7) The relay contacts FAULT MONITOR of
the connection plate allow to connect addi-
tional units for alarm transmission. The
power rating of the relay contacts is 1 A at
24 V or 120 V~.
8) If a 24 V operating voltage is required, e. g.
for an additional alarm relay, this voltage
can be picked off at the terminals "24 V "
of the connection plate. The power rating
9