Herunterladen Inhalt Inhalt Diese Seite drucken

Railcom: Activating The Blanking Interval (Cutout) In The Lv102; Lv102 - Lenz Elektronik Digital Plus LV102 Information

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

24
7
RailCom: Activating the blanking interval (cutout)
in the LV102:
Use "PoM" ("Programming in operational mode") to activate RailCom.
Before making any settings, familiarise yourself with PoM practices in
combination with the manual control LH100 or LH90. When activating
the RailCom function, the LZV100 must be switched on.
The following procedure activates the blanking interval (cutout) both in
the amplifier component of the LZV100 as well as in the each of the
LV102 amplifiers that are connected to the terminals CDE of the
LZV100.
When using a command station LZ100 (from software version 3.5),
you will use this command station to activate the blanking interval
(cutout) in the LV102 amplifiers that are connected to the terminals
CDE.
Proceed as follows:
• Select any locomotive address on the manual control. Don't
worry: If a locomotive with the selected address is placed on the
track during activation, its settings will not be affected because
CV7 can only be read but not changed.
• Change to "PoM"
• Select CV7
• Program the value 50 into CV7. This switches the LZV100 / LV102
into setting mode; the LED of the LZV100 / LV102 shows a double-
flash.
• You have 15 seconds to program the value 93 for activating the
RailCom function into CV7. The LED will shine constantly and
RailCom is activated.
If you want to deactivate RailCom (i.e. disable the blanking interval
(cutout)), proceed as follows:
• Change to "PoM"
• Select CV7
• Program the value 50 into CV7. This switches the LZV100 into
setting mode; again, the LED of the LZV100 shows a double-flash.
• You have 15 seconds to program the value 92 for deactivating the
RailCom function into CV7. Again, the LED will shine constantly
and RailCom is deactivated.