4.5 Power-on
-
When the heater is switched on, the temperature of the sauna is showed on the display.
-
Optionally, the display can be set to show the remaining power-on time or to alternate between
the time and the temperature - see the point Settings.
-
As soon as the heater reaches the predetermined temperature, the On/Off LED starts glowing
green, and the elements will not be powered.
-
Once the heater has cooled down to such an extent that the elements will be powered again,
the On/Off LED will again glow red.
-
The heater remains operational if the power outage lasts less than three minutes. When the power
supply resumes after a power outage of less than three minutes, the heater will resume its operation
from the point where it was before the outage. If the outage lasts longer than three minutes, the
heater is switched off. The settings will always stay in the memory despite duration of the outage.
4.6 Settings
-
When the heater is switched on, the power-on time, which will be saved in memory, can be
set within about one minute. After this, the heater goes into its normal operating mode, and any
subsequent settings of the power-on time will only affect the current heating session.
-
When the SET button is depressed, the yellow LED will flash, and an array of zeros will be displayed.
-
After this, the desired preset time can be selected in steps of 30 min. using the + /- buttons.
-
The preset time setting is saved in memory by depressing the SET button a second time.
-
After that, the green LED will flash to indicate that you are now able to set the power-on time via
the +/- buttons. The remaining power-on time saved in the memory, will be displayed first.
-
After having set the desired power-on time via the +/- buttons, press the SET button again.
Now, the desired power-on time will be saved in memory.
-
After the SET button is depressed, the red LED will flash. The temperature setting saved in the
memory, will be displayed first. You can then set the desired temperature via the +/- buttons.
The temperature can be set on the scale 60 °C-115 °C. After this, depress the SET button one
more time to make the heater go into set mode, where the LEDs are continually illuminated to
indicate the current status.
- If the yellow LED is illuminated, the preset timing is active,
and the remaining preset time is being displayed.
- If the On/Off LED is illuminated red, the heater is switched on, the heating elements
are turned on, and the temperature in the sauna is being displayed (default value).
- If the On/Off LED is illuminated green, the heater is switched on, but the elements are switched
off for the moment – the temperature in the sauna is being displayed (default value).
-
Once the heater has been set, the set values will remain in memory, and when power is switched
on via the I/O button, the heater will always be warmed up in the same way for the same set period
of time. The preset time, however, will always be zero. If you wish to apply the preset timing
feature, you will always need to activate it separately.
-
If the SET button is not pressed after the setting, the LED will continue flashing for about one
minute. After this, the heater will automatically return to its normal operating mode, and the settings
will be saved in memory.