Display functions, overview
LED
State
LED green
operating mode
adjustment mode empty
adjustment mode full
OES mode
locking mode
LED yellow output disabled
output enabled
OES mode, nc
LED red
uncertain operating range
error message
Adjustment to empty (adjustment mode)
Ensure that the medium to be detect-
ed is not in the sensing area of the
sensor. Activate the *Teach-In ele-
ment "SET" for max. 5 s. The green
LED flashes slowly. When the element
is deactivated, the measured value for
the empty state is stored. The unit
returns to the operating mode.
Note:
When the unit is adjusted to the empty state, it automatically suggests
a possible measured value for the full state. Any measured value for
the full state which may have been stored previously is overwritten.
This suggested measured value is calculated on the basis of the empty
state which has just been measured and a signal distance set at the
factory. Under normal conditions safe functioning is guaranteed with-
out adjustment to the full state.
Adjustment to full (adjustment mode)
Ensure that the medium to be detected is in the sensing area of the sen-
sor.
Activate the *Teach-In element "SET" for min. 5 s and max. 10 s. First
the green LED flashes slowly and after 5 s it flashes quickly. By deacti-
vating the element the measured value for the full state is read.
11
PAGE
Display
off
slow flashing (1Hz)
fast flashing (2Hz)
slow flashing (1Hz)
off
off
on
slow flashing (1Hz),
together with LED green
slow flashing (1Hz)
fast flashing (2Hz)