1.
Motor power supply during the opening 230/120 VAC
2.
Motor common terminal
3.
Motor power supply during the closing
4.
Power supply phase wire 230/120 VAC
5.
Power supply neutral wire 230/120 VAC
6. - 7.
Blinker 230/120 VAC - 40 W
Power supply output 24 VAC / 3 W for photocells and
8. - 9.
other attachments
Opening command for connections to: button panel,
10.
key selector. Normally open contact
11.
STOP command. Normally closed contact
12.
Common (-)
13.
Photocell. Normally closed contact
14.
Antenna cable shielding
15.
Antenna
CONNECTIONS TO THE TERMINALS
and PHOTOCELL) should be connected to the common wire (-).
STATUS INDICATORS OF THE UNIT INPUTS
L1
L2
L3
L4
L5
L6

PROTECTION FUSES

F1 = 5 A
F2 = 160 mA
F3 = 250 mA
12
CAUTION: Unused inputs that are normally closed (STOP
Programming
Lights up when a pulse is received at the START input
terminal
Goes out when a pulse is received at the STOP input terminal
Goes out when a pulse is received at the PHOTOCELL
input terminal
Goes out when a pulse is received at the opening limit
switch input terminal
Goes out when a pulse is received at the closing limit
switch input terminal.