5) Try to put 1 to 8 digit random false codes to the keypad to test its safety. The keypad generates 5 beeps for each
unsuccessful code entry after the # button is pressed. The keypad locks during 30 seconds after 10 successive
false codes are entered. Normal operation will be resumed after the 30 seconds are expired.
NOTE:
The maximum allowable time for SUCCESSIVE DIGIT and CODE entry are 10 seconds and 30
seconds respectively. The keypad refreshes itself automatically after 30 seconds of silence even some
false codes were entered.
11. Reprogram the Keypad for other Operation Modes
6) To access to PROGRAMMING MODE, enter your Personal Master Code and validate via *.
3 2 8 9
7) Set Relay Output 1 in Start/Stop Mode.
4 1
#
8) Set keypad to activate DURESS OUTPUT after 10 successive false codes.
7 1
#
9) Re-program is finish. To leave programming mode, validate via *.
*
12. Use the Keypad with the Reprogrammed Data
10) To command Relay Output 1, enter the User Code 1 and validate via #.
8 3 2 1
In Start/Stop operation mode, it is necessary to enter Code 1 again to STOP Output 1. If Output 1 is for door
strike application, it is suggested to work with a door sensing switch to initiate the auto re-lock (STOP) function, in
which, enter code 1 for re-locking is not necessary.
11) Try to put 1 to 8 digits false codes to the keypad to test its safety. The keypad will activate the DURESS
OUTPUT after 10 successive false codes are entered. To reset (deactivate) the Duress Output, you are required
to enter the composition of the User Code 1 and validate via #.
12) In case of wrong data entry in operation, press # to cancel, then re-try; or wait 10 seconds, then re-try.

13. Specifications

* Operation Voltage
* Current Drain
* Operation Codes
* Code Combinations
* Relay Outputs
HAA85WP
The keypad is in Programming Mode & ready to receive new data.
*
Output 1 has been changed from Momentary to Start/Stop
with Accelerated code.
The keypad has been changed from locks 30 seconds to
activates Duress Output
The keypad is back to operation mode.
The re-programmed data have been stored.
Relay output 1 starts
#
: 12V DC (10-14VDC)
: 15 - 150mA
: User Code 1, 2 & 3, Super User Code, Master Code, Duress Code, & Accelerated
Code
: 111111100
: Output 1 -- 5 Amp, Other outputs -- 1 Amp