Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions For Electrical Connection; Electrical Connection; Controlling A Drive / Single-Pole Roller Blind Switch - RADEMACHER RTBS serie Einbau- Und Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety instructions for electrical connection

For any work on electrical systems, there is a risk to life due
to electrocution.
Only a certified electrician may connect the tubular motor to the
power connection, or do any work on electrical systems, and only
in accordance with the connection diagram in these instructions.
Disconnect the feed from the grid on all poles, and secure it
against unintended connection.
Test the system for zero voltage.
Perform any installation and connection work only with the power
disconnected.
Damaged cables present a short circuit hazard.
Run all cables in the roller blind box, such that they cannot be
damaged by moving parts.
Electrical connection (Figure
9
Controlling a drive with a single-pole roller blind switch
Control device
e.g., single-pole
switch/button
GRID
230 V/50 Hz
38
D
ES F
(15)
L 1 ( / )
L 1 ( / )
N
PE
M
M
4
Switch unit
3
L1
N
PE
GB NL
For fixed installation devices...
...A disconnect must be present for each phase on the installation
side, according to DIN VDE 0700. Switches with a contact opening
width of at least 3 mm (e.g., circuit breakers, fuses, or residual
current devices).
Short circuit hazard due to water if cables are improperly routed.
Never route the motor cable (15) directly vertically, or water may
run down the cable into the motor and destroy it. Route the cable
in a loop. The loop ensures that water running down the cable is
collected at the lowest point and drips from there.
)
9
1.
Run the motor cable (15), after mounting the motor, in the
junction box or switch box provided for it.
Color codes for motor conductors (15)
L 1
=
L 1
=
N
=
PE
=
Installation layout and connection diagram for mounting on the
right side.
STOP
Rotational direction 1
(black)
Rotational direction 2
(brown)
Neutral line
(blue)
Ground
(green/yellow)
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rtb serieRtbm serie

Inhaltsverzeichnis