3. Operation

3.1

Installation Space Requirements

CAUTION!
Installation and maintenance has to be done by authorized personnel only
who are familiar with all valid safety rules and guarantee the adherence of
these rules.
Do not operate unit if there is danger of explosion.
Unit is not watertight (protection class IP 44). Make sure that no water can
enter.
Try to avoid places of installation with direct solar radiation in warm
surrounding areas
+max °C
–min °C
CAUTION!
The unit requires air from the outside and generates off-heat that needs to be
conducted to the outside. Please take this into account when considering
possible locations.
Front
Exhaust air
3.
Operati on
Make sure when choosing an installation space of the EFOY
ProEnergyBox that the temperature ranges of the EFOY Pro fuel
cell and the EFOY Fuel Cartridges do comply.
The air openings must not be blocked.
Install only in upright position.
Make sure that the device does not exceed the
maximum inclination.
Inclination: 20° max.
The air openings need to be free.
Supply air
12