• When the battery voltage is above 14.5±0.5VDC, the regulator goes in over-
charge protection mode. The power from the solar panel input connector [11] is
cut off to prevent damage to the battery until the voltage drops below 13.5VDC.
• Over-load protection mode: when the output voltage is beyond limits, the fuse
[10] on the back of the regulator melts to prevent damage to the regulator. To
re-use the regulator, the fuse needs to be replaced by a new one with the same
specifications.
• Reverse polarity protection: in order to prevent possible damage the regulator
will not function when reversed connecting polarity is detected. Correct the
polarity to use the regulator.
7.

Technical Specification

Load current (max.)
Solar input current (max.)
Fuse
Over-charge protection
Over-discharge protection
Operating temperature
Humidity
Dimensions regulator
weight
Recommended battery (not incl.)
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use
of this device.
For more info concerning this product, please visit our website
www.velleman.eu.
The information in this manual is subject to change without prior notice.
00 (15/09/2008)
SOL10UC
10A
10A
10A
14.5V ~ 15.0V
11V (±0.5V)
-10°C ~ 42°C
≤80%
145 x 165 x 80mm
±900g
Sealed Lead Acid, deep cycle