7.2.2 Temperature Area ...

This view allows you to define image areas to be specially moni-
tored with regard to temperature measurement Firstly, tempera-
tures in these areas can be determined more accurately by entering
the emissivity and the distance of the object to be measured
Secondly, temperature values can be defined for these areas
When these values are exceeded, a warning will be displayed or
an alarm will be triggered, for example
1) In the category "Area ID", select the range "Area 1– 7" or select
"Full Image" when the settings are to be applied to the entire
image In the category "Area Name", a name can be entered
for the area selected
2) To define one of the areas "Area 1– 7", drag the mouse to draw
a rectangle over the desired image section The rectangle will
flash After you click "Apply", the rectangle will be displayed
with clearly defined corners and its number
3) In the category "Target Emission Rate", enter the emissivity ε
and in the category "Target Distance" the distance of the object
to be measured in the area selected
4) If you do not only wish to measure the maximum temperature
of an area but also to indicate a warning or trigger an alarm at
a given temperature, select the type of alarm in the category
"Alarm Type"
Threshold Alarm: warning and alarm will be triggered as soon
as the given temperature is exceeded
Temperature Difference Alarm: warning and alarm will be trig-
gered as soon as the temperature deviates by the difference
value defined
5) Enter the threshold /difference values for indicating a warning
and for triggering an alarm into the fields "Warning Value"
and "Alarm Value"
All warnings and alarm events will be logged They can be
retrieved via "Configuration  Device Log  Alarm Log" In case
of alarm, the button
to acknowledge the alarm, the log will automatically appear
18
will appear When you click this button
6) Use the category "Output Channel" to define whether or not
an alarm output OUT1/ OUT2 (11) will be activated in case of
alarm (setup options of the alarm outputs
 Alarm  I /O Alarm")
7) In the schedule below the thermal image, define the validity for
the temperature alarm of the area The days from Sunday to
Saturday are shown vertically; the hours are shown horizontally
When a box is blue, alarm detection has been activated for this
30-minute period To change the status, click the box To change
the status for a whole day or for the entire schedule, click
8) Use the category "Enable" to activate /deactivate the alarm
feature and the log feature for the area in general
9) To save the changes to the camera, click "Apply"
Configure additional image areas for surveillance, if required

8 Resetting the Camera

When the camera is reset to its factory settings, any changes the
user has made to the camera settings will be lost
1) Release the screw (3) of the cover and open the compartment
2) Keep the Reset button (22) pressed for more than 5 seconds
(
☞ 
fig 4 in chapter 4) Release the button Resetting will start
with a delay and may take a few minutes
3) Tightly close the cover again
The camera will be reset to the static IP address 1921680121
The default user name and the password for log-in is: admin
 "Configuration