- Make sure that the 2 levelling screws D are not tightened;
Fig. 4 - stage 2.a.
- Take the hood, tilt it and hook it on to the bracket as shown
in Fig. 4 - stage 1.
- Once the structure has been positioned, secure it to the
bracket by coupling the nut with the screw; Fig. 4 - stage 2.
- Tighten the nut with a spanner, leaving a gap of at least 3 mm
between the nut and the bracket as shown in Fig. 4 - stage 3.
Align the appliance horizontally using the two levelling screws
D Fig. 5 - stage 1.
- Once the adjustment is complete, fit the hood in a permanent
manner with the screws B and nuts C Fig. 5 - stage 2 and 3.
- When carrying out the fixing operations, use only screws
and screw anchors suited to the type of wall (e.g. reinforced
concrete, plasterboard etc.).
If the screws and screw anchors are supplied with the appli-
ance, make sure that they are suited to the type of wall to
which the hood must be fixed.
• Attention!
Before proceeding with the installation of decorative flues fit
the electrical system box E.
- Lift the electrical system box; Fig. 6 - stage 1.
Position the bracket E in correspondence of the 3 screws G
already arranged on the bushing and tighten them as shown
in Fig. 6 - stage 2 - 3 - 4.
• Installation of models with decorative ducts - extrac-
tor hood
Make sure the electrical power supply is within the measure-
ments of the decorative connector.
Adjust the width of the support bracket of the top connec-
tor (Fig. 7).
Then fix it to the ceiling so that it is on the same axis as the
hood using screws A and observing the distance from the
ceiling shown in (Fig. 7). Connect flange F to the air exhaust
hole using flexible hose L (Fig.8).
Take care not to scratch the duct; wear gloves when removing
the protective film. (Fig. 9)
Slide the top connector inside the lower duct and place this
on the body (Fig. 10).
Pull out the top duct as far as the bracket and secure it using
screws B (Fig. 7).
To transform the hood from a ducting version into a filtering
version, ask your dealer for the charcoal filters and follow the
installation instructions.
• Filtering version:
Install the hood and the two flues as described in the
paragraph for installation of the hood in ducting version. To
assemble the filtering flue refer to the instructions contained
in the kit. If the kit is not provided, order it from your dealer
as accessory. The filters must be applied to the suction unit
positioned inside the hood. They must be centred by turning
them 90 degrees until the stop catch is tripped (Fig. 2- stage 3).

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
The effective performance of the cooker hood depends on
constant maintenance; the anti-grease filter and the active
carbon filter (Fig. 2 - stage 3) both require special attention.
• The anti-grease filter is used to trap any grease particles
suspended in the air, therefore is subject to saturation (the
time it takes for the filter to become saturated depends on
the way in which the appliance is used).
- To prevent potential fire hazards, the anti-grease filters
should be washed a minimum of every 2 months (it is pos-
sible to use the dishwasher for this task).
- After a few washes, the colour of the filters may change.
This does not mean they have to be replaced.
If the replacement and washing instructions are not fol-
lowed, the anti-grease filters may present a fire hazard.
• The active carbon filters are used to purify the air which
is released back into the room. The filters are not washable
or re-usable and must be replaced at least once every four
months. The active carbon filter saturation level depends on
the frequency with which the appliance is used, the type of
cooking performed and the regularity with which the anti-
grease filters are cleaned.
• Clean the cooker hood frequently, both inside and outside,
using a cloth which has been dampened with non-abrasive
liquid detergents.
• The light on the cooker hood is designed for use during
cooking and not for general room illumination. Extended
use of the light reduces the average duration of LED lamp.
• Replacing LED lamps (Fig.11).
If the appliance version is with LED lamps, the intervention of
a specialised technician is necessary to replace them.
• Commands (Fig.12):
- To activate the functions put your hand in front of the sensor
at a distance of no more than 8 cm.
Sensor:
1 - Indicated LED lamp = This lamp is will light on or off when
IRed sensor is detected.
2 - IRed sensor = This sensor emits infrared light when an
electric current passes through it.
3 - Photo transistor = This sensor receive the reflected
infrared signal.
Sensor A = Activate the "ON/OFF" function or the "Cleaning
mode" function.
- ON/OFF
Activates or switches off all functions.
- To activate it place your hand in front of the sensor.
- When the LED switches on the hood functions are ready
to be activated.
Attention! If one interrupts hood operation with the rel-
evant sensor and one does not activate any other function
within 10 minutes, the hood switches OFF automatically.
Therefore, if you wish to restart the hood again, you must
place your hand in front of the sensor A (on/off ).
- To disable the function repeat the operation.
- Cleaning Mode
Blocks all functions to prevent switching the product on
accidentally during cleaning operations where are in front
of the hood.
- To activate it put your hand in front of the sensor for ap-
proximately 4 seconds.
- When the LED lights up followed by a multiple sound signal
the function is active.
- To deactivate the function repeat the operation.
Sensor B = Activates the "TIMER" function or the "CLEAN
AIR" function.
- Timer