6
www.aeg.com
5. CONTROLS
The hood is fi tted with a control panel with
aspiration speed selection control and a
light switch to control cooking area lights.
Use the high suction speed in cases
of concentrated kitchen vapours. It is
recommended that the cooker hood suction
T6
T2
1
Speed ON/OFF button
Control panel on/off key
2
Suction speed (power) key 1
3
Suction speed (power) key 2
4
Suction speed (power) key 3
5
Suction speed (power) key 4
Note: suction speed (power) key 4 has
a limited duration of 10 minutes, after
which the previous suction speed is
reactivated.
6
Suction speed (power) key 5
Note: suction speed (power) key 5 has
a limited duration of 5 minutes, after
which the previous suction speed is
reactivated.
7
"Breeze" function key
(Room ventilation)
The hood switches on at low suction
speed (power) for 60 minutes, after
which it switches off.
8
Filter saturation control and
activation/deactivation key
9
Indication of active Hob
function
10
Ambient light ON/OFF key
11
Lights ON/OFF key
Note: hold key down to adjust the
intensity of the light
T6
T6
T6
T3
T4
T5
H
2
is switched on for 5 minutes prior to cooking
and to leave in operation during cooking
and for another 15 minutes approximately
after terminating cooking.
The control switches are located on the
unit's front panel:
T6
T6
T6
T6
T7
T8
Control panel on/off function
With the hood in standby, press key1, all
led lights will switch off: the control panel
is off.
Press key
the control panel is active.
Carbon fi lter saturation control activation/
deactivation function
With the hood in standby, press key
longer than 3 seconds
Key
saturation fi lter has been activated.
Key
the carbon saturation fi lter has been
deactivated.
Filter saturation control and reset
function
At regular intervals and depending on
the hood temperature, key
up to indicate that the fi lters need to
be maintained in accordance with the
instructions in the relative paragraphs.
Key
required on the grease fi lters
Key
required on the carbon fi lter.
ood
Filter saturation indicator reset
With the hood in standby, press key
longer than 3 seconds.
Repeat the operation if necessary.
T6
T9
1
again, all led lights will turn on:
8
will fl ash to indicate that the carbon
8
will remain lit to indicate that
8
on with a fi xed light: maintenance is
8
on and fl ashing: maintenance is