Overview of contents
Safety notes . . . . . . . . . . . . . . . . . . . B - 1
Product description . . . . . . . . . . . . . B - 1
Features and operation . . . . . . . . . . B - 1
Care and maintenance . . . . . . . . . . . B - 1
Trouble shooting . . . . . . . . . . . . . . . B - 1
Technical data . . . . . . . . . . . . . . . . . B - 1
This publication replaces all previous announcements. No part of this
publication may be reproduced, processed using electronic systems,
replicated or distributed in any form, without our written authorisation.
Subject to technical changes. All rights reserved. Names of goods are used
without guarantee of free usage keeping to the manufacturer's syntax.
The names of goods used are registered and should be considered as
such. We reserve the right to modify design in the interest of ongoing
product improvement, such as shape and colour modifications. The scope
of delivery may vary from that in the product description. All due care has
been taken in compiling this document. We accept no liability for errors or
omissions. © TROTEC
®

Safety notes

This manual should be read carefully before
setting up / using the apparatus, and it should
always be kept close to the place of use or on
the machine!
The apparatus was subjected to extensive mate-
rial, function and quality tests before delivery.
Nevertheless, dangers can arise from the use of
the apparatus if it is incorrectly used by untrained
personnel!
Intended use and disclaimer:
• If your blower does not work, miss parts, was
dropped, damaged, left outdoors or dropped into
water, return it to an Autorized Service Center.
• Do n ot p ut a ny o bject i nto v entilation o penings.
Do not operate with ventilation openings blocked;
keep free of dust, lint hair or anything that may
hinder the air flow.
• Extreme caution is necessary when the blower
is used near children or invalids.
• Do not use an extension cord with this air blower.
Do not pull or carry by cord, use cord as handle,
pull cord around sharp edges or corners. Keep
cord away from heated surfaces.
• To reduce the risk of electric shock, do not expose
to rain. Store indoors. Do not handle plug or the
air blower with wet Hands.
• Unplug unit from outlet when not in use and
before servicing. Turn off blower before un-
plugging.
• Do not use this air blower with any solid state
speed control device.
• Do not use or store near hazardous, toxic, flam-
mable or explosive materials. Do not operate
this blower near combustible liquids, explosive
dust or gases like gasoline or other fuels, lighter
fluid, cleaners, oil-based paints, natural gas,
hydrogen, coal dust, magnesium dust, grain
dust or gun powder.
G
m
The operation of any air blower
can result in foreign objects being
blown in the eyes, which can result
in severe eye damage. Always wear safety
goggles complying with EN code. Everyday
glasses have only impact resistant lenses,
they are not safety glasses. Glasses or gog-
gles not in compliance with european stan-
dards can seriously hurt you.
To reduce the risk of hearing damage, wear
ear protectors if in the vicinity of where a
blower is operating for an extended period
of time, or when using it in a noisy area.

Product description

The blower is designed to move large volumes
of air. It can either be used to dry wet carpets,
floors and furniture, even the hard to reach; or
provide moisture control and even excellent air
circulation.

Features and operation

• Level the blower out of the carton and pull off the
protective plastic bag. With a soft cloth remove
the packing lint if any. Uncoil the power cord
then, connect the plug to an appropriate outlet.
Your blower is ready to use. Just place the blower
in the desired operating position.
• To turn the blower on, just
turn switch to the High (1),
Med (2) or the Low (3) set-
ting. To turn it off, just turn
the switch to the Off (0)
position. The TFV 10 S has
only one Speed, you only
can turn the blower on
and off.
• The blower is designed to work on three posi-
tions (see the figures).

Care and maintenance

• Inspect the electrical cord and the wiring for
damage or discoloration.
• Clean the screens on the side and the front of
the unit.
• Listen for abnomal sounds.
• Keep the unit clean.
• Make sure the ground pin or grounding prong is
intact or the blower will be unsafe to operate.
Operating manual radial fan TFV 10 S / TFV 30 S
• Use compressed air or vacuum to remove lint,
dust etc., from motor, screens or blower wheel.
Do not use a pressure washer to clean the unit.
• Always consult a qualified electrician or your
dealer for accessing the internal of the unit.
Trouble shooting
• Unit does not run:
- Check if the switch is turned on.
- Check if the power cord is damaged.
• Units runs briefly and shuts off:
- See if the grill is obstructed.
- The motor bearing / wiring is faulty,
consult your dealer.
Technical data TFV 10 S
Air volume . . . . . . . . . . . . . . . . . . . . . . . 525 m
Operating voltage . . . . . . . . . 230V / 50Hz (0,5 A)
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1 kW
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . plastic
Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . portable
Dimensions . . . . . . . . . . . . 300 x 275 x 330 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . .3,75 kg
Technical data TFV 30 S
Air volume Step 1 . . . . . . . . . . . . . . . . 2.050 m
Air volume Step 2 . . . . . . . . . . . . . . . . 2.850 m
Air volume Step 3 . . . . . . . . . . . . . . . . 3.500 m
Operating voltage . . . . . . . . . 230V / 50Hz (5,2 A)
Capacity . . . . . . . . . . . . . . . . . . . . . . max. 1,2 kW
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . plastic
Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . portable
Dimensions . . . . . . . . . . . . 545 x 515 x 490 mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18,5 kg
In the European Union electronic equip-
ment must not be treated as domestic
waste, but must be disposed of profes-
sionally in accordance with Directive
2002/96EU of the European Parliament
and Council of 27th January 2003 concerning old
electrical and electronic equipment. At the end
of its life please dispose of this instrument in a
manner appropriate to the relevant legal requi-
rements.
/h
3
/h
3
/h
3
/h
3
B - 1