Model SP4/SP6
1. Remove the pump from the aquarium tank or in-line setup; remove the pump base.
2. Using a Phillips screwdriver (cross-headed screwdriver), unscrew the screws and remove the impeller cover from the pump motor.
3. Using a flathead screwdriver, carefully lift out the impeller assembly (with magnetic ceramic shaft). Please refer to screwdriver symbol
on top of impeller assembly to know where to apply screwdriver.
4. Remove O-ring.
5. Clean all components in clean water only, using a small, nonabrasive brush, if necessary. DO NOT USE DETERGENTS OR OTHER
CHEMICAL CLEANERS which could damage the pump and pollute the aquarium.
6. Reassemble all components with care in reverse order. Ensure that the impeller bearing, bushing and Rubber Support are correctly
placed at the bottom of the impeller well.
7. Before replacing the pump back in the tank or set-up, rinse the threaded fittings in clean water to remove any residual dirt or debris.
1
THREADED FITTINGS
a) The threaded fittings have to be hand tightened until they fully fit on input / output pump threaded connections.
b) During maintenance operation check that the pump's Input and Output threaded connections are free from dirt, debris and/or any
obstructions to avoid problems during the threaded fittings installation. Clean the pump's Input and Output threaded connections
by rinsing them in tap water.
c) To avoid damaging the pump's threaded connections, the pump itself must be always be stable and securely installed on a flat and
levelled surface.
d) Using a Phillips (cross-headed) screwdriver, tighten the screws until they fully fit. Afterwards tighten an additional quarter turn the
screws.
CAUTION
a) The threaded fittings should easily assemble/disassemble. If you feel you are applying excessive force in order to fit the threaded
fitting coupling to the pump's corresponding threaded connections, then do not continue the installation as the threaded connec-
tions could be damaged. Proceed by removing the threaded fittings and cleaning both the connections and the fittings in tap water.
b) Extreme care should be considered when using accessories not included with the pump. Do not use tooling for tightening
connection accessories as the force produced can damage the pump threaded connections.
c) Do not use glues or sealants for fixing on the pump's threaded fitting or different connection accessories not included with the
pump first sale configuration.
d) Before installing the threaded fittings, it is recommended, as a good and common practice, wrapping the input / output pump
threaded connections with some Teflon.