5.1.2 P1-Self-adjusting preset in absolute mode
Parameter in line 33 = 1. XP reference point is "0" (absolute value).
Preset P1 will act as a presignal to preset P2. P1 will be automatical-
ly „taken along" when targeting preset P2. Typical application: Swit-
ching from high to low speed, P1 is to be defined only once. Input
Start XP will activate the relay outputs Out P1 and Out P2 and set
the directional signal. Relays Out P1 and Out P2 are deactivated on-
ce the targeted preset value is reached or by Stop XP .
Start
XP
P2
P1
Out P1
Out P2
Directional
signal
P1-Self-adjusting preset - absolute mode with LOOP
Parameter in line 34. Example: Loop = 360. Typical application: Rota-
ry table positioning. Input Start XP will activate relay outputs Out P1
and Out P2 and set the directional signal within the smallest rotation
angle. See diagram.
Start
XP
LOOP=360
P1
180°
Out P1
Out P2
Directional
signal
www.baumer.com
P2
P2
P2
P1
P1
P1
P2