6.4. Starting

Before first boiler's use there should be checked: leakproof of the threaded joints (whether there
isn't any leak) installation water level, the parameters of boiler's operating are to be set as well.

6.5. Burning up

The steps to be taken to burn up in the boiler:
1. Switch off the power.
2. Push the chimney flap (gas pass opened).
3 . Place splinters and some bigger wood pieces to the boiler upper chamber .
4 . Burn the paper and close the upper door .
5. Open the bottom door as to provide natural draught.
6. Wait for about 15÷20 min. for better wood burning.
7. Put that much of wood to get the right quantity of embers which will cover boiler's bottom
(ca. 10 cm) (chopping of the wood in about 5 cm pieces at the first stage of burning up
accelerates embers' producing) .
8. Wait for 15÷20 minutes for the ember layer occurring.
9 . Fill up the whole combustion chamber .
10 . Close the upper and bottom door hermetically .
11. Pull the chimney flap and switch on the fan.
12 . When the boiler reaches 60
WARnInG!
It is forbidden to switch on the fan when the upper door is opened.
IMPORTAnT!
It is important to pay an attention on both depth of gasificat-ion chamber and
thickness of the upper door while chamber's loading. If wood's sizes aren't adequate
to the elements mentioned above it may be difficult to close boiler's door or load
the chamber with wood. You must not close the door by force - it may cause door's
damage.
IMPORTAnT!
Wood storing for about a year ensures its right humidity (admissable humidity - 25 %
- look at TECHnICAL DATA section). Advisable humidity level (15 %) is to be obtained
after 2 years wood storing (look at the diagram no 7).

6.6. Fuel loading

If the boiler is chosen adequate to the place to be warmed up there is one loading for 8÷12 hours
needed. It is advisable however to control the boiler every 5÷7 hours. To control wood quantity
you should:
1. Switch off the boiler with the main switch.
2. Open the chimney flap.
3 . Open the upper door and load the chamber if it's necessary .
4. Close the door, chimney flap and switch on the boiler.
It is important not to let the fuel to get between combustion chamber and chimney flap as it
would obstruct chimney flap's closing.
When loading (it is recommended to burn out the fuel up to embers) there is a need of taking
down ash deposited on the loading chamber's sidewall .
38
C fan will start working automatically .
°