Herunterladen Diese Seite drucken

AIV 65 0869 Einbauanleitung Seite 8

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Removal / Decommissioning
The capacitor needs to be discharged before removing. Please use the same bulb as before.
Pinch off the battery and interpose the bulb between the plus and minus pole of the capacitor.
As soon as the loading light expires the capacitor is discharged.
Mounting Guidelines / Connection Scheme
Please use massive ring cable lugs. Furthermore check if the system is secured correctly.
Please do not install the main fuse further away than 30 cm from the battery. (see above)
-
ground
This manual is copyrighted. Every reproduction and reprint also extracts and every reproduction of an
image also in an altered state are only permitted with written authorisation of AIV GmbH + Co. KG
fuse
+
Batterie
© Copyright 2010 by AIV GmbH + Co. KG
power capacitor
+
ground
- 4 -
amplifi er
ground

Werbung

loading

Diese Anleitung auch für:

65 0870