4. Specifications

4.1 Connections

Power
Rated voltage
Operating voltage
Rated current
Rated frequency
Connection
Connector size
RS-422/485
Electrical specification
Data rate
Connection
Connector size
Circuit type
RS-232
Electrical specification
Data rate
Connection
Circuit type
Line interface
Electrical specification
Data rate
Connection
Connector size
Circuit type

4.2 Isolation between interfaces

Power to all other
FSK-Line to all other
GB.20
TD-29 AC
115 V/230 VAC
104–132/207–264 VAC 12–36 VDC
24 mA/12mA
48–62 Hz
3-pos. screw terminal
2
0.2–2.5 mm
(AWG 24-12)
RS-422/485
2 400 bit/s–19.2 kbit/s
5-position screw terminal
0.2–2.5 mm
TNV-1, twisted pair, shielding not required
RS-232
2 400 bit/s–19.2 kbit/s
9 position D-sub, DCE
SELV, max 15 m length, shielding not required
2 400 bit/s–19.2 kbit/s
2 position screw terminal
0,2–2,5 mm
TNV-3
AC: 3 kV RMS @ 50 Hz and 60s duration
DC: 1 kV RMS @ 50 Hz and 60s duration
1.5 kV RMS @ 50 Hz and 60s duration
TD-29 DC
24 VDC
200 mA
2-pos. screw term. 2-pos. screw term.
2
(AWG 24-12)
2
(AWG 24-12)
TD-29 36–55 VDC
48 VDC
36–55 VDC
50 mA
6611-2001